background image

INSTALLATION INSTRUCTIONS

WARNING:  

• Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring. 

• Never wire any electrical device with power turned on. Wiring dimmer with power on 

  may cause permanent damage to dimmer and void warranty.

• If you are not sure about any part of these instructions, please contact a 

  licensed electrician.

CAUTION: 

1.  Use only with 120V AC 60 Hz.
2.  Do not exceed maximum rating of the dimmer as indicated on the device.
3.  Must be installed and used in accordance with electrical codes.
4.   If a bare copper or green ground connection is not available in the wallbox, contact a 

licensed electrician for installation. 

5.   For use ONLY with permanently installed 120V AC incandescent/halogen fixtures.
6.   To avoid overheating and possible damage to other equipment, do not use to control 

receptacles, fluorescent lights, motor-driven appliances, transformer supplied 

appliances, etc.

7.   Use only #14 or #12 copper wire rated for at least 75º C with these devices.
8.  Minimum Lamp Wattage:

  Single Location Control = 60 Watts. 

  Multi-location Control = 100 Watts

NOTES:

1.  The RF Master Dimmer (VL-9534-MD-X) is wired directly to the light fixture.

2.  For multi-location installations one RF Master Dimmer is used with RF Accessory

  Dimmer(s) VL-9542-AD-X.

3.  The VL-9542-AD-X requires hardware connection to the RF Master Dimmer.  Refer to  

  installation instructions for wiring.

4.  The RF Master Dimmer is not compatible with standard 3-way switches.

5.  For multi-location installations, the RF Master Dimmer is the only device that is  

  included in the RF Network.

6.  Do not exceed maximum load of 600 watts.

Z-Wave Device Network Installation Instructions for RF Master Dimmer Only:

1.  This product may be added to a new or existing Z-Wave network. The device has a

  blue LED, which will blink when the device is not included in a Z-Wave network. The 

  LED stops blinking when the RF Master Dimmer is in a network.

2.  To include this device in a Z-Wave network, select the command on your Z-Wave  

  controller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then  

  press the RF Master Dimmer ON/OFF switch one time to include it in the network.  

  The LED will stop blinking.

3.  To exclude this device from a Z-Wave network, select the command on your  

  Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node,  

  Exclude Device, etc.). Then press the RF Master ON/OFF switch one time to exclude  

  it from the network. The LED will start blinking.

4.  This product works with other Z-Wave products from different vendors and  

  product categories as part of the same network.

5.  This product is a listening node and it will act as a repeater in the Z-Wave  

  network. It will perform the repeater function with Z-Wave products.

6.  For multi-location install; blue LED will blink on all wired units, when the RF Master  

  Dimmer (VL-9534-MD-X) is not included in the Z-Wave network.  After including the  

  RF Master Dimmer in the Z-Wave network, the LED will stop blinking.  The

  VL-9542-AD-X (no neutral) Accessory Dimmer need not be included in the Z-Wave

 network.

IMPORTANT:

RF Master Dimmer will not work or will become damaged if wired incorrectly and the 

warranty will be voided. 

Troubleshooting Guide

Symptom

Possible Cause

Solution

No Function. LEDs is OFF

A) Light bulb(s) burned out

B) Circuit breaker is off or 

tripped

C) Disconnect switch on the 

dimmer is pulled out to the 

OFF position

D) Improper wiring

E) Defective dimmer

A) Replace light bulb

B) Turn on the circuit breaker

C) Push in the disconnect 

switch on the dimmer

D) Check and correct wiring

E) Replace dimmer

Erratic operation or flickering 

LEDs

A) Lamp power is less than 

60 Watts 

B) Loose wiring connections

A) Increase lamp power to at 

least 60 Watts

B) Check and correct wiring

Functions normally using the 

dimmer push buttons but not 

from Z-Wave controller and 

one of the blue LEDs blinks 

ON and OFF about once per 

second

Dimmer is not included in 

Z-Wave network

Include dimmer in a Z-Wave 

network using a Z-Wave 

controller. Refer to Z-Wave 

controller user manual for 

details

Functions normally using the 

Master dimmer control but 

not from Z-Wave controller 

and no LEDs are blinking

Problem with RF 

communication on dimmer

A) Relocate Z-Wave controller

B) Replace dimmer

Functions normally both lo-

cally and from a Z-Wave con-

troller but can’t be controlled 

from a dimmer accessory 

switch (VL-9542-AND-X) or 

other Z-Wave device

The dimmer accessory or 

other Z-Wave device is not 

associated with the dimmer 

you wish to control

Create an association 

between the dimmer acces-

sory or other device and the 

dimmer. Refer to your Z-Wave 

controller user manual for 

details

Dimmer is warm to touch 

after a period of time

This is normal

No action required

(Cut if necessary)

Strip 5/8”

Suggested Tools

ON/OFF SWITCH

  •  Press once to turn lights ON at previously selected level. 

  •  Press again to turn lights OFF.

  • When lights are OFF, press and hold for 2 seconds for full brightness.

  •  When lights are ON, press and hold for 2 seconds until the blue LED blinks. After the 

preset delay, the lights will begin fading to OFF (up to 4 minutes).

  • ON/OFF LED indicates that dimmer is turned on.

READ BEFORE INSTALLATION!

Switch Identification

ACCESSORY

ACCESSORY

ACCESSORY

Master Control

(VL-9534-MD-X)

Accessory

(VL-9542-AD-X)

Disconnect Switch

Red

Black

Green

Green

Blue

Blue

RF MASTER DIMMER – VL-9534-MD-X FOR INCANDESCENT FIXTURES ONLY / NO NEUTRAL REQUIRED

RF ACCESSORY DIMMER – VL-9542-AD-X

Reviews: