QUICK GUIDE MILKSHUTTLE
Urban GmbH & Co. KG • T49 (0) 4484/9380-0 • www.milkshuttle.de
Page 2
For DIMA firmware 3.x starting with serial no. H7
scroll up with (plus-key)
scroll down with (minus-key)
Save selected value with key
SET Feeding
3: >0.3<
The preselection key 3 is now programmed for the dispensing mode and free dosing is now
possible. Dosing out is started and ended by pressing a
S
tart
/S
top
key (on the dosing nozzle,
on the drawbar head or on the membrane keyboard).
Leave the programming mode by pressing the Set key. The new dosing amount has been stored and
takes effect.
PROGRAMMING THE DISPENSED FEED AMOUNTS /DISPENSING MODE
Use the
+
or
-
keys to set the desired value (in litres).
Keep
F
eeding
key pressed for 2 seconds, this will call up the feeding mode.
Briefly press the key that you would like to program (here: key
2
).
Keep
S
et
key pressed for 2 seconds in order to call up the programming mode.
K
ey
Set
Key to be pro-
grammed (here:
key
2
)
SET Feeding
2:>03,0<
dispensed amount of feed
(in litres), old value
SETTINGS (D
aTE
/T
ImE
, U
NITS
, L
aNGUaGE
, S
ErIaL
NUmbErS
, W
arNING
LEvELS
TEmpEraTUrE
mIN
/
max
)
2
+
-
+
-
+
-
SET
SET
SET
SET
SET
SET
INFO
ESC
SET Feeding
3: >START/STOP<
SET Feeding
3: >30<
At the upper and lower end of the value scale the value START/STOP will be shown.
-
+
Key to be pro-
grammed (here:
key
3
)
+
-
a) Programming the dosing amount
b) Programming the dispensing mode
SET
Start
Stop
CALIBRATION OF DOSING PUMP
We recommend having the dosing pump calibrated on a regular basis. This process is
described in detail in Chapter 7.2 of the manual.
Make sure that the main menu is active (date and time must be shown in the display of the operating
panel). If required, press
eSC/i
nFo
key in order to switch to the main menu.
Press
S
et
key briefly in order to call up the programming mode.
Use the
+
or
-
keys to set or select the desired value.
If required, press
Set
key again in order to switch to next value.
Finally, briefly press
S
et
key in order to exit programming mode. The new
value is now stored and takes effect.
Use
+
or
-
keys to scroll through the settings/parameters. Stop at the parameter you would like to set
(date/time, language, etc.).
Keep
S
et
key pressed for 2 seconds in order to call up the
settings
menu.