INSTALLATION - ***********PLEASE READ BEFORE INSTALLATION

CHILLER FOUNTAIN DETAIL

1.  The CF200 Fountain must be installed by a qualified plumber in accordance with National plumbing

        & drainage code AS/NZS 3500.1 and AS/NZS 3500.2 and qualified electrician in accordance with

        AS3000 regulations as well as local authority codes.

2.  Before Installation FLUSH ALL EXTERNAL LINES before connecting to fountain to help prevent

        blockage caused by debris.

3.  Provide adequate level surface for mounting fountain as specified in local area codes.  Installation

        under shade would be prefereable.  M12 Dynabolts required for installing on to concrete surface.  

        Incorrect installation will affect the fountain performance.  Urban Fountains and Furniture will not be

        responsible for defects that arise from incorrect installation.  All fountains have been checked for

        leaks as part of our quality assurance program and some droplets of water may be evident inside 

        the packaging and/or unit. This is perfectly normal. 

5.  This fountain uses waterpush fittings - see back for quick release instructions.   A sample fitting has

        been supplied to familiarise the plumber with method of connecting and disconnecting the fittings.

        Stretching and pulling will result in damage of the fitting and possible leaking at connectors.

6.  Ensure that the water lines are replaced correctly when re attaching the chiller unit.   

7.     

Water flow ball cock regulator is mounted directly below the water nozzle. Access is via removal of 

        side panel.   Adjusting may be required depending on site water pressure.  

8. 

Depending on the water pressure available, the bubbler flow can be altered by adjusting the stop

        cock directly below the bubbler.   Access via the access door.   *****Allen Key Supplied.

9.    The 

water cooler

 has an adjustable thermostat access via access door

10.   Recommended minimum and maximum ambient temperatures for correct operations of water

        cooler are from 5 C to 50 C respectively.

11.   Main line water supplies must be separated by a shut off valve.

12.   The water cooler must be earthed. Never wire directly to power supply.   Earthing points provided.

13.   Always ensure the correct security screwdriver is used when undoing external bolts.

14.   All maintenance tools and replacement parts can be purchased individually from the manufacturer. 

        The water filter should be replaced approximately every 6-8 months.

TROUBLESHOOTING

There is restricted or

 no water flow?

The water continues

to drip / run after 

shutting off?

Leaking from the 

internal connections?

The water flow is 

shooting over the top of

the basin or is not high

enough and trickling

over the nozzle?

Check the inlet lines for kinks in the tubing. Ensure the water

supply valve is fully open. Check the water pressure regulator is open.

The water pressure is too high / low and needs to be adjusted via the

water flow regulator so it flows in to the catchment area of the basin.

Check that they have been installed correctly.  (all fountains are leak

tested prior to leaving the factory).  Have the push in fittings been pulled? 

(see instructions on how to connect and disconnect push in fittings).

Is the water inlet connection tight?

The most common cause of water not shutting off is a leaking valve and 

is due to the lines not being flushed adequately and debris getting in to 

the valve through the inlet and sitting on the rubber seals.

To check the valve it will need to be removed.  Please contact this office

for details instructions to ensure this is done correctly.