background image

Variable 
Control 

 
 
 
 
 
 

Igniter 

 
 
 

 

TO TURN ON THE HEATER 

 
1.

 

Push and turn the gas control knob counter-clockwise 90

°

 and hold it. 

2.

 

At the same time press the igniter until the flame comes on.  

Note: If a 

new cylinder has just been connected, please allow one minute for the 
air in the gas pipeline to purge out.

 

3.

 

Release the gas control knob and check the flame stays on. 

4.

 

If the flame goes out repeat steps 1 to 3. 

5.

 

Release the gas control knob and turn it to maximum temperature in 
fully counter-clockwise direction. 

6.

 

A 5 minute complete shut-off period is necessary before re-lighting the 
heater. 

 

TO TURN OFF  

 

1.

 

Turn gas control knob clockwise to the stop position. 

2.

 

Depress gas control knob and turn clockwise to shut off. 

3.

 

Turn the gas cylinder off completely

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Construction and Characteristics 

 

Steel housing, pole and base. 

 

Stainless steel burner with safety tilt shut-off. 

 

Stainless steel flame screen. 

 

Variable pilot control panel with flame failure device. 

 

Heavy duty wheels. 

 

Heat emission from reflector 

 

 

 

 

 

 

 

 

 

       5 

1.

 

Cylinder Base 

2.

 

Cylinder tank housing 

3.

 

Post 

4.

 

Cylinder housing support 

5.

 

Base of control housing 

6.

 

Air admittance fences 

7.

 

Burner base 

8.

 

Flame emitter screen 

9.

 

Reflector  

10.

 

Gas valve controller 

 

OPERATION & STORAGE

 

PARTS & SPECIFICATIONS

 

Summary of Contents for BFX770

Page 1: ... Urban Industry Limited All rights reserved www patioheaters4u com Printed in the UK Model No BFX770 Terrace Patio Heater Operating Instructions Safety Information 2 Assembly Parts 4 Setting Up 6 Heater Stand Location 9 Leakage Testing 11 Operation Storage 12 Before Requesting Help 13 Technical Data Specifications 14 Guarantee 15 Certified Please retain this manual for reference ...

Page 2: ... lightening misuse neglect including poor maintenance incorrect adjustment or repair transit damage wear and tear use in improper manner or inconsistent with the technical safety standards in force 4 If at any time the appliance has been dismantled or repaired by an unqualified service person the guarantee shall become void 5 The purchaser s sole and exclusive remedy under this guarantee against U...

Page 3: ...and maintenance is required Prior to each use check the patio heater for any wear to the hose regulator pilot and burner Do not transport heater while it s operating All leak tests should be done with a soapy solution NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS Check the heater immediately if any of the following exists o The heater does not reach temperature o The burner makes a popping noise duri...

Page 4: ...ll LPG cylinder Opening blocked Clean pipes Air in supply system Purge air from lines Loose connection Check all fittings Worn tilt switch Replace tilt switch Pilot will not Thermocouple worn Replace thermocouple stay on Loose connections Tighten connections Debris around pilot Clean dirty area Gas leak in line Check connections Lack of fuel pressure Low fuel in cylinder Burner will Thermocouple w...

Page 5: ...e complete shut off period is necessary before re lighting the heater TO TURN OFF 1 Turn gas control knob clockwise to the stop position 2 Depress gas control knob and turn clockwise to shut off 3 Turn the gas cylinder off completely 12 Construction and Characteristics Steel housing pole and base Stainless steel burner with safety tilt shut off Stainless steel flame screen Variable pilot control p...

Page 6: ...r leak test while smoking If you cannot stop a leak turn off the gas supply and call your gas supplier The heater must be checked with a full cylinder Do not use the heater until all connections have passed a leak test Only use parts recommended Substitute parts can void the warranty Gas connections on the appliance are leak tested at the factory prior to shipment A complete gas tightness check mu...

Page 7: ... 4 3 Thread the hose down the post assembly 4 4 Fix the burner base vertically with the post ensuring the instruction label is below the ignitor and facing same direction STEP 5 5 1 Install 4 pieces of M6 x 10mm bolts and tighten each one 5 2 Locate hose at base of pole and thread on a jubilee clip 5 3 Fit the regulator supplied to hose and attach jubilee clip and tighten as shown STEP 6 6 1 Put 3...

Page 8: ...or use only Always ensure adequate fresh air ventilation Always maintain proper clearance to combustible materials i e top 50cm 18 inches and sides 60cm 24 inches minimum see figure 1 Heater must be placed on firm level ground The heater must conform to local codes and storage handling of LPG Never operate heater in an explosive atmosphere where petrol or other flammable liquids or vapours are sto...