background image

 10. Care of Your Fan and Troubleshooting 

Care of Your Fan

Here  are  some  suggestions  to  help  you  

maintain your fan.

1.  Because  of  the  fan’s  natural  movement, 

some  connections  may  become  loose. 

Check the support connections, brackets, 

and blade attachments twice a year. Make 

sure they are secure. (It is not necessary to 

remove fan from ceiling.)

2.  Clean your fan periodically to help maintain 

its new appearance over the years. Do not 

use water when cleaning, this could damage 

the  motor,  or  the  wood  or  possibly  cause 

an  electrical  shock.  Use  only  a  soft  brush 

or lint-free cloth to avoid scratching the 

finish. The plating is sealed with a lacquer 

to minimize discoloration or tarnishing.  

Warning - Make sure the power is off  

before cleaning your fan.

3.  You can apply a light coat of furniture polish 

to the wood for additional protection and 

enhanced  beauty.  Cover  small  scratches 

with a light application of shoe polish.

4.  There is no need to oil your fan.  

The  motor  has  permanently  lubricated 

sealed ball bearings.

MAKE  SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX 

BEFORE YOU ATTEMPT TO MAKE ANY REPAIRS. REFER TO THE SECTION, 

“MAKING ELECTRICAL CONNECTIONS.”

Fan will not start
 

Fan sounds noisy

1.  Check main and branch circuit fuses or breakers

2.  Check line wire connections to the fan and switch wire connections in 

the switch housing. CAUTION: Make sure main power is off.

1.  Make sure all motor housing screws are snug.

2.  Make sure the screws that attach the fan blade bracket to the motor hub 

are tight.

3.  Make sure wire nut connections are not rattling against each other or 

the interior wall of the switch housing. 

CAUTION: Make sure power is off.

4.  Allow a 24-hour “breaking in” period. Most noises associated with a 

new fan disappear during this time.

5.  Make sure the canopy is a short distance from the ceiling. 

It should not touch the ceiling.

6.  Make sure your electrical box is secure and rubber isolator pads were 

used between the mounting bracket and electrical box.

Troubleshooting

Problem Solution

Summary of Contents for UHP9220

Page 1: ...UHP9220 UHP9221 UHP9222 ...

Page 2: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 9 10 10 11 ...

Page 3: ...ctrical connections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the electrical box and ungrounded conductor on the other side of the electrical box 11 Electrical diagrams are for reference only Light kits that are not packed with the fan must ...

Page 4: ...embly 6 Blades 3 7 Light Kit Pan 8 Light Kit Fitter Assembly 9 Glass Shade 10 Wall Control 1 Mounting Bracket inside canopy 2 4 5 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring attached 4 Decorative Motor Collar Cover 2 Unpacking Your Fan Unpack your fan and check the contents You should have the following items a b ...

Page 5: ...oxes Figures 1 2 and 3 are examples of different ways to mount the electrical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum allowable angle is 30 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 TO REDUCE THE RISK OF FIRE ELECTRIC SH...

Page 6: ...y Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Figure 7 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the hanger pi...

Page 7: ...d with the electrical box Note that the flat side of the mounting plate is toward the electrical box Figure 8 3 Tighten the two screws on the electrical box securely 4 Carefully lift the fan assembly up to the ceiling mounting plate Make sure the tab on the mounting plate is properly seated in the groove in the hanger ball Figure 9 Figure 8 Washers 120VWires ULListed Electrical Box Ceiling Mountin...

Page 8: ...cuit breaker panel remove the existing wall plate and switch 2 Proceed to connect the wires as follows make sure the fan and light slide switches of the wall control are set in OFF position Connect the solid black wire from the wall control to the black wire from the fan Connect the red or blue wire from the wall control to the black wire from the fan Connect the black with white stripes wire from...

Page 9: ... Run the fan for 10 minutes Finishing the Fan Installation STANDARD CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mounting screws firmly 2 Install the remaining two mounting screws into the holes in the canopy and tighten firmly 3 Install the deco...

Page 10: ...ght kit pan clockwise tighten the screws Re install the screw that was removed in step 1 and tighten firmly Figure 13 3 Remove one screw from the light kit pan and loosen but do not remove the other two screws Connect the wires from the light kit assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch ca...

Page 11: ...located at the top of the motor housing refer to figure 7 on page 4 to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse airflow Figure 16 Figure 17 Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 16 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Re...

Page 12: ...f shoe polish 4 There is no need to oil your fan The motor has permanently lubricated sealed ball bearings MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire conne...

Page 13: ... FAN SIZE SPEED VOLTS FAN POWER CONSUMPTION WITHOUT LIGHTS WATTS AIRFLOW CFM AIRFLOW EFFICIENCY HIGHER IS BETTER CFM WATT NET WEIGHT GROSS WEIGHT CUBE FEET 52 Low 120 9 1999 222 14 77 Lbs 16 54 Lbs 1 43 High 42 4306 103 ...

Reviews: