In case of an empty cylinder, the DL
EMPTY LED will switch on.
In case of a fault, the DL FAULT LED will
switch on.
By opening the cylinders door, besides
the DL TAMPER turning on, the relay will
switch as well.
Max power applicable on the outputs is
100mA
E - Example of connection of FAST PRO PLUS outputs with inputs of an alarm normally opened
F - Example of connection of FAST PRO PLUS outputs with balanced inputs of an antitheft
The outputs shown in the diagram are not
always necessary, but only in cases where
the voltage of pull-up resistance is lower than
that of power supply.
The UR Fog outputs are normally opened
and connected with input zones of the
alarm control panel normally opened.
In this diagram, by putting a resistance with a
value required by the alarm control panel
used, in UR Fog terminal with not used
outputs the central will see the correct
resistance.
After the activation of an output, a pull-down
will occur causing the alarm in the
corresponding zone.
DL EMPTY
DL FAULT
DL TAMPER
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
PRO PLUS
+ 12 V
GND
RELE’ TAMPER
D - Example of connection of FAST PRO PLUS outputs to drive LEDS and / or relays
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
CENTRAL ALARM
+
L1
L2
L3
L4
FAST PRO PLUS
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
CONFIRM OUT
+12V OUT
GND OUT
VALIDATION IN
FAST PRO PLUS
12