In this diagram, putting the resistance value required by the alarm control panel used in the terminal UR Fog, with
not used outputs the central will see the correct resistance, while following the activation of an output, you will
have a pull-down causing the alarm of the corresponding zone.
12 FRONTAL LEDs
BLUE
LED
ON
and
FIXED
signals the machine is armed and ready to shoot, if the heater has
reached the working temperature
ON
and
FLASHING
signals a fault.
See paragraph
17
FAULTS AND POSSIBLE SOLUTIONS
RED LED
It is
ON
when at least one cylinder is empty
See paragraph
14
CYLINDERS EXCHANGE
AND
RESET
GREEN LED
ON
and
FLASHING
indicates the heating process is in progress At this point, Fast
01 is not ready to shoot.
ON
and
FIXED
Fast 01 is hot and ready for fog emission.
IF BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND FROM THE BUZZER, A SERIOUS
ANOMALY IS DETECTED. SEE PARAGRAPH 17
13 SHOOTING TIME SETTING
To set the shooting time, after opening the cylinders compartment
door as showed in
Paragraph 5
, at the top of the PCB, you must
put the P3 jumper to the left position (closer to the S1/S2
buttons).
Then, holding down the S1 "SET", 3 LEDs on the front will start
flashing and each flash is equivalent to one second.
If you press the button again, the shooting time is not added to the
one previously set, but will restart from zero.
N.B. The button in the cylinders compartment showed in next paragraph, is linked to Set/Reset button,
Therefore, after setting shooting time, it is recommendable to place the P3 jumper in RESET position (right
side), in order to make this operation without removing the cover and avoid to zero shooting time.
Installation and use manual FAST 01 NEW 220V Page 11 of 21