Section 2 - Service and Repair
Hydraulics
114101-000 X26 Ultra Narrow - Service Manual
Page 2-25
S
E R I E S
P
A R A L L E L
M
A N I F O L D
It is not necessary to remove the manifold to perform all maintenance procedures (i.e. replacing a single
valve).
Refer to
Section 3 - Schematics
for the hydraulic schematic and hose routing diagram.
R
EMOVAL
AND
I
NSTALLATION
Figure 2-18:
Series Parallel Manifold Location
1. Turn the wheels straight, then open
both module doors to gain access to
the manifold.
W A R N I N G
!
!
Before disconnecting the battery
negative (–) lead, make sure all switches
are OFF. If ON, a spark will occur at the
ground terminal which could cause an
explosion if hydrogen gas or fuel vapors
are present.
2. Disconnect the battery pack connec-
tor and the battery negative (–) lead.
3. From the control module side;
• tag and disconnect wires.
• tag, disconnect and plug the side
hoses.
4. From the front, tag, disconnect and
plug the front hoses.
5. Remove the three capscrews and
nuts while supporting the manifold.
6. Remove the manifold.
Figure 2-19:
Series Parallel Valve Manifold
Installation is reverse of removal. Torque mounting cap-
screws to 24 N-m (
18 ft./lbs.).
1
5
3
2
4
1. Bracket
2. Capscrew (3 each)
3. Washer (6 each)
4. Nut (3 each)
5. Series Parallel Manifold
1
2
3
2
1. Manifold Block
2. 3 Way - 2 Position Valve
3. Flow Divider/Combiner