5.
LR / P2-1
will appear in the display:
High
will be displayed when the
left rear
outrigger is in contact with the ground and
Low
will be displayed when it is not.
Verify this by operating the micro switch.
The value should change from Low to High
6. Use the [RIGHT ARROW] to select
RR
/
P2-2
:
High
will be displayed when the
right rear
outrigger is in contact with the ground and
Low
will be displayed when it is not.
Verify this by operating the micro switch.
The value should change from Low to High
7. Use the [RIGHT ARROW] to select
RF
/
P2-3
:
High
will be displayed when the
right front
outrigger is in contact with the ground and
Low
will be displayed when it is not.
Verify this by operating the micro switch.
The value should change from Low to High
8. Use the [RIGHT ARROW] to select
LF
/
P2-4
:
High
will be displayed when the
left front
outrigger is in contact with the ground and
Low
will be displayed when it is not.
Verify this by operating the micro switch.
The value should change from Low to High
9. Use the [RIGHT ARROW] to select
Extend
/
P2-5
:
High
will be displayed when the
auto level
switch
is activated and
Low
will be displayed
when it is not.
10. Use the [RIGHT ARROW] to select
Retract
/
P2-6
:
High
will be displayed when the
auto stow
switch
is activated and
Low
will be displayed
when it is not.
NOTE:
If none of the above indicates a problem contact
Snorkel or your local service agent.
❑
EZcal auto level calibration procedure
Under no circumstances change any other
parameter of the auto level board (other than
those specified here) without permission
from Snorkel International.
Death or personal injury and serious damage
to the machine can result from altering
parameters beyond those specified.
1. Manually level the machine on its stabilisers.
2. Plug the EZcal into the auto level board (see
Figure 1)
3. Turn on the SR ignition.
The display screen will show:
4. Press the [RIGHT ARROW] twice to scroll to
the Access Level 3 screen.
The display will show:
5. Press [ENTER]
The display screen will show:
6. Use the [UP & DOWN ARROWS] to change
the numbers and the [LEFT & RIGHT
ARROWS] to change the cursor position.
Change the code '0000' to the correct code
to reach access level 1.
Press [ENTER]
The display screen will show:
8. Press [RIGHT ARROW] twice to select
machine setup
The display screen will show:
9. Press [ENTER]
Use the [RIGHT ARROW] to select the
calibrate level function.
The display screen will show:
page 20
SR3370 & SR2770 (CE) – 12864B
Maintenance Information
DANGER
GP122 MENU:
HELP:PRESS ENTER
GP122 MENU:
ACCESS LEVEL 3
GP122 MENU:
ACCESS LEVEL 1
ACCESS LEVEL:
CODE 0000
GP122 MENU:
MACHINE SETUP
Summary of Contents for SR2770
Page 1: ...SERVICE PARTS MANUAL POWERED ACCESS WORK PLATFORM X27 33RT ...
Page 2: ......
Page 10: ......
Page 56: ......
Page 60: ......
Page 64: ......
Page 76: ...page 3 2 SR3370 SR2770 CE 12864B ...
Page 78: ......
Page 83: ...TITLE Ground Box Sheet 1 Snorkel Models SR3370 SR2770 Ground box drawing sheet 1 Page 3 9 ...
Page 84: ...TITLE Ground Box Sheet 2 Snorkel Models SR3370 SR2770 Ground box drawing sheet 2 Page 3 10 ...
Page 85: ......
Page 92: ......
Page 96: ......
Page 97: ......