background image

03

NO.

Items

-20°C

Testing method

Internal resistance 

3

≤130mΩ

50% battery SOC state frequency of 1 KHZ ac 
resistance tester. 

Criterion

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage. Store the battery at 
various temperatures for 2h and discharge the 
battery with 0.33C to the cut-off voltage. 

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual
capacity ≥80%

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (0.33C)/CV (14.6V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 
charged capacity is no more than 80% of normal 
value. Accumulated times is defined as cycle life.

4

Cycle life (DOD%100)

≥2500 cycles

5

UE-24Li200

4. Product Performance

6

Recovery
capacity ≥90%

Rest for 1 hour after fully charged, then discharge with 
0.33C current until the battery reaches the discharge 
cutoff voltage. Repeat above process for three times, 
if the discharge time is not less than 120 minutes, you 
can stop and define the Discharging current*time 
value (Ah) as battery capacity.  

Rated Capacity 

1

200Ah

Minimum Capacity 

2

190Ah

5. Protective Circuit Specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized 
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, 
short circuit. Overall, the BMS helps to ensure safe and accurate running.

Items

Over-charge protection for each cell

Specification

Content

3.80±0.03V

Over charge

Over-charge release for each cell

3.60±0.05V

Over-charge release method

Under the release voltage

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Summary of Contents for UE-24Li200

Page 1: ...5 12KWh Rated Capacity Minimum Capacity Energy Floating charge voltage Internal resistance Limited charge voltage 25 6V 25 6V 27 6 0 2V 2 3 4 5 7 8 Nominal Voltage Outgoing Voltage 20m 29 2 0 2V Stand...

Page 2: ...t Conditions 3 1 1 Unless otherwise specified all performance tests is required conducted at temperature 25 C 2 C Humidity less than 45 75 RH 3 1 2 Unless otherwise specified the tested product is req...

Page 3: ...e life DOD 100 2500 cycles 5 UE 24Li200 4 Product Performance 6 Recovery capacity 90 Rest for 1 hour after fully charged then discharge with 0 33C current until the battery reaches the discharge cutof...

Page 4: ...y MOSFET over temperature Release 90 5 C Protection 100 5 C Short press a switch light and display screen voltage temperature residual capacity current light up after waiting for screen to go out afte...

Page 5: ...V Pin2 to B Pin2 to A and Pin4 to GND 2 The LCD panel socket Pin1 to 12V Pin2 to B Pin2 to A and Pin4 to GND 3 Battery iron box matching LCD communication shielding line length is about 1 5 m www upow...

Page 6: ...row the battery into water Do not put the battery in a charger or equipment with wrong terminals connected Never connect the positive and negative of battery with metal Avoid excessive physical shock...

Page 7: ...on Battery when not in use for a long time because of its own self discharge charac teristics can also cause discharge to prevent the occurrence of a discharge battery should maintain a certain capaci...

Reviews: