UPM THM101B Owner'S Manual Download Page 1

THERMOSTAT

THM101B

OWNER’S 
MANUAL

FEATURES

Read and understand this 
manual before installation or 
use.

• Easy-to-read LCD display
• Easy-to-set temperature 
   settings
• Heat–OFF–Cool and fan 
   auto-on switch

This thermostat can replace common residential thermostats and it is 
designed for use with most electric, oil or gas heating and air conditioning 
systems that use low voltage control.

Note: 2 x “AA” batteries are required for operation.  Ensure batteries are installed.

INSTALLATION

PAGE 1

PAGE 2

PAGE 3

PAGE 4

PAGE 5

PAGE 6

PAGE 7

PAGE 8

PAGE 9

PAGE 10

FAN

ON

AUTO

COOL

OFF

HEAT

COOL

ON

Approximately 5’ (1.5 m) from the floor.

This thermostat should be mounted:

CHOOSING A LOCATION FOR A NEW THERMOSTAT

Near or in a frequently occupied room, preferably on an inside partitioning wall.
On a section of the wall 

without

 pipes or duct-work.

Near a window, on an outside wall, or next to a door leading outside.

This thermostat should NOT be mounted:

Exposed to direct light or heat from the sun, lamp, fireplace, or other heat radiating 
objects which may cause false readings.

Near or in a direct airflow from supply registers and return-air grilles.
Near concealed pipes and chimneys.

In areas of poor air circulation, such as behind a door or in an alcove.

System Type
Gas - Standing Pilot 
Gas - Electronic Ignition
Gas - Fire Boiler
Gas - Millivolt System
Oil - Fire Boiler
Oil - Fire Furnace
Electric Furnace
Electric Air Conditioner
Baseboard Electric Heater (120/240 V)
Heat Pump/Multi-stage equipment

Compatible with thermostat

Yes
Yes

Yes

Yes

Yes

Some models

Some models

No
No

Yes

COMPATIBILITY

Generally, equipment with 

low voltage

 control is compatible with the thermostat.  For details 

on compatibility of your particular equipment, please call technical support at 1-888-468-6876.

* NOT COMPATIBLE WITH ANY 120/240 V CIRCUIT.

 

INSTALLATION

The following tools may be required for installation:

(      ) screwdriver

Masking tape

 (To wrap the exposed wires temporarily and labeling the disconnected wires)

Wire stripper/cutter

 (If necessary, to strip wires)

Power drill with a 3/16” bit

 (If necessary, to drill holes on the wall)

Level

 (If necessary, to level the thermostat)

INSTALLATION

REPLACING OLD THERMOSTAT

TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker panel.

Carefully unpack your new thermostat and mounting plate; save package of screws, 
instructions and receipt.

Remove cover from old thermostat. If it does not snap off when pulled firmly from the 
bottom, check for a screw used to secure the cover.

Loosen screws holding thermostat to the wall and lift away the thermostat.

Disconnect wires from old thermostat or sub-base. As you disconnect each wire, use 
masking tape to label it with the old terminal designation. If there are only two wires, 
they don't need to be labeled. 

If there is an extra wire that is not connected to your old thermostat, then you won't 
need to connect it to the new thermostat.

After choosing a location for the new thermostat, you may arrange to have a 
heating contractor install the control wiring for you.

Do not operate the cooling system when outside temperature is below 10

 

(50 ) to avoid damaging the compressor.

°C

°F

*

Test the system to make sure that your heating and cooling systems are working 
properly before installation.  If either does not work, contact a local heating/air 
conditioning service person to fix the problem before installation.

Take care not to let the wires fall back into the wall or let the ends of the wires touch 
one another.

The wires are usually designated 'W', 'Y', 'G', 'R’

INSTALLATION

MOUNTING THE THERMOSTAT BACK COVER

The back cover should be mounted with the large hole on the top.

Thread the existing wiring through the large hole from the back and set the back 
cover flat on the wall.

Select two appropriate mounting holes and mark the locations with a pencil.  If 
necessary, use a level to make sure the thermostat is leveled.

Remove the back cover from the wall and drill two 3/16” holes in the marked screw 
positions.

Insert the wall anchors into the holes completely.  If necessary, use a hammer to
tap-in lightly.

Mount the back cover, with the two screws, to the wall.  Make sure the terminals are 
on the top-half of the back cover.

Carefully separate the back cover from the thermostat by disengaging the 4 latches 
found at the corners on the back of the thermostat.  Pull firmly but DO NOT try to pry 
open with a screwdriver.

INSTALLATION

CONNECTING THE WIRES TO THE TERMINALS

Depending on your heating/cooling equipment, you may 
need to connect 2 to 5 wires to the thermostat.

If your old thermostat has a ‘C’ wire, please wrap it with 
electrician’s tape as it is not used with this thermostat.

If you have both an ‘R’ and ‘Rc’ wire, you may connect 
them together to the ‘R’ terminal of the thermostat.

If you are unsure of the connections, or for new 
installation, you may refer to the wiring diagrams below.

Connect the previously labeled wires to the corresponding terminals, matching the 
designations.  Use a screwdriver to securely fasten the wires onto the terminals.  Make sure 
the wires do not short-circuit with other terminals.

Cooling Relay

Fan Relay

Heating Relay

WIRING DIAGRAM

Heating Relay

Heating Relay

Fan Relay

2-wire heating

4-wire heating/cooling

3-wire heating

INSTALLATION

SETTING THE FAN OPERATION JUMPER

Depending on your home’s heating system, you may need to change the jumper setting for 
the fan operation.  The jumper is located above the battery compartment.

HG

 - Use this setting for gas or oil-fired furnaces.  This setting allows the fan 

operation to be controlled by the heating system; not the thermostat.  This is the 
correct setting for most systems.

HE

 - Use this setting for electric heating systems.  With this setting, the thermostat 

will turn on the fan immediately with the heating system.

The jumper is pre-installed in the ‘

HG

’ position as a factory default.  So there is no need to 

change the jumper if this is the correct setting.

To change the jumper setting, pull out the small black rectangular block and align it to the 
new position and push in fully.

INSTALLATION

BATTERY INSTALLATION

2 “AA” size batteries are required for operation.  The battery symbol (       ) will flash when the 
batteries are low.  It is recommended that the batteries be replaced at least once a year.

Remove the back cover from the thermostat.

Insert the 2 “AA” size batteries into the battery compartment following the correct 
polarity as marked.

Immediately following the battery installation, the thermostat will enter the °C/°F 
selection mode.  The current temperature will appear with the temperature scale 
(in °C) flashing.

SELECTING THE DISPLAY IN  C or  F

°

°

Re-attach the back cover.

NOTE: To select the temperature display format in °C or °F, it must be done immediately 
            following the battery installation.

Use the 

UP

 or 

DOWN

 button to select the desired temperature scale (in °C or °F).  

Otherwise, if no buttons are pressed within 12 seconds, °C will automatically be 
selected, and the thermostat will go to its operation mode.

NOTE: Selecting the °C or °F display is a one-time process.  Therefore, if you wish to change 
            it at a later time, you will need to reset the thermostat by pressing the RESET key
            above the battery compartment and select °C or °F using the UP or DOWN button.

Attach the thermostat body to the back cover (that is already installed on the wall) by 
carefully aligning the two pieces and firmly snapping the 4 latches at the back of the 
thermostat.

ATTACHING THE THERMOSTAT TO THE BACK COVER

TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker before wiring.

DISPLAY / BUTTONS

button placement

UP BUTTON

DOWN BUTTON

FAN

ON

AUTO

COOL

OFF

HEAT

COOL

ON

1

2

1
2

OPERATION

“HEAT–OFF–COOL” SWITCH

OFF position:

- If the switch is to the OFF position, both the heating and cooling system controls will be 
turned OFF.

If the heating or cooling system is turned ON, the “ON” icon will appear and 
continue to flash.

HEAT position:

- Slide the switch to the HEAT position to control the heating system.
- The “

HEAT

” icon will light up when the switch is on the HEAT position.

COOL position:

- Slide the switch to the COOL position to control the cooling system.
- The “

COOL

” icon will light up when the switch is on the COOL position.

FAN ON/AUTO SWITCH

For automatic control of the fan, set the FAN ON/AUTO switch to the AUTO position.  
In cooling, the fan starts/stops with the cooling equipment.  In heating, the fan is 
controlled by the heating equipment and usually starts a few minutes after the 
heating equipment turns on.

To turn on the fan manually, set the FAN ON/AUTO switch to the ON position.  The fan 
will run continuously to improve air ventilation.  To return to automatic control, set the 
switch to the AUTO position.

OPERATION

TEMPERATURE SETTING

Press the 

UP

 or 

DOWN

 button once to enter the temperature setting 

mode.  The “      ” icon will appear, and the display will now show the 
current SET temperature flashing.

1

Press the 

UP

 or 

DOWN

 button to adjust to the desired set temperature.

NOTE: Press and hold the button 
down to accelerate the setting.  If no 
button is pressed within 12 seconds, 
the display will automatically return 
to the current temperature display.

2

The temperature can be set in increments of 0.5

°.

The temperature setting range is from 5

°C to 35°C (41°F to 95°F).

OPERATION

CURRENT TEMPERATURE DISPLAY

The current room temperature is normally displayed 
on the LCD screen.  The “      ” icon is lit when the 
current room temperature is displayed.

The displayed temperature range is from 0°C to 60°C 
(32°F to 140°F).  Beyond this, the display will show 
either “HI” or “LO”.

The resolution of the detected temperature is 0.1°.

VIEWING THE SET TEMPERATURE

Pressing either the 

UP

 or 

DOWN

 button 

once

 will 

reveal the current SET temperature.  The “      ” icon 
will appear and the current SET temperature will be 
flashing.

NOTE: There is a built-in delay action to protect the heating and cooling systems.

- When the heating system is ON, it will keep on running for at least 2 minutes even if there 
  is a change in the temperature setting.
- When the heating system is OFF, it will remain OFF for at least 2 minutes before it can 
  come back ON.
- When the cooling system is ON, it will keep on running for at least 4 minutes even if there 
  is a change in the temperature setting.
- When the cooling system is OFF, it will remain OFF for at least 4 minutes before it can 
  come back ON.

DISPLAY AUTO-RETURN

In any setting mode, if no button is pressed within 12 
seconds, the display will automatically return to the 
current temperature display.

TROUBLESHOOTING

LIMITED ONE-YEAR WARRANTY

Disengage the latches to 
separate the back cover
from the thermostat

LEVEL

+

+

Mark the locations
with a pencil

Metal terminals

Back cover

Wall

Back cover

Metal 
terminals

Wires

HEAT

HEAT

HEAT

PROBLEM

SOLUTION

“HEAT–OFF–COOL” SWITCH

3

FAN ON/AUTO SWITCH

4

4

3

PAGE 11

PAGE 12

PAGE 13

PAGE 14

HG

HG

HE

HE

HG

HG

HE

HE

LCD screen is blank.

The battery symbol (          ) is 
flashing.

Heat will not come on.

Heat will not come on but the 

ON

” icon is flashing.

Air conditioning will not come on.

Air conditioning will not come on 
but the “

ON

” icon is flashing.

- Check if the batteries are installed correctly.
- Check if the batteries are fresh and of the correct type.
- Press the RESET key on the back of the thermostat above the battery compartment.

- This is an indication that the batteries are running low.  Replace with fresh alkaline   
  batteries.
- Note: We recommend to have the batteries replaced at least once a year even if the battery 
  symbol is not flashing.

1) Check and ensure that the thermostat is set to the HEAT mode.
2) Check and ensure that the set temperature is 

higher

 than the current (room) temperature.

3) You may have to wait up to 2 minutes before the heat will turn on.  The thermostat has a   
    built-in time delay to prevent undesirable on/off sequences.
4) After a 2-minute wait, the heating should now be on.  Whenever the heating system is 
    running, the “

ON

” icon will be flashing.

1) Check if the furnace switch and/or pilot flame is turned on, as it may have been turned off.
2) Allow several minutes for the heating system to heat up and the fan to activate.  Most 
    heaters will heat up the system for a short while before warm air can be ventilated by the 
    fan.  Also check that the HE/HG setting is set correctly.  (Refer to page 7).
3) If the heat still does not come on, check the wiring installation again.  (Refer to page 6).

1) Check and ensure that the thermostat is set to the COOL mode.
2) Check and ensure that the set temperature is 

lower

 than the current (room) temperature.

3) You may have to wait up to 5 minutes before the air conditioning will turn on.  The 
    thermostat has a built-in time delay to protect the air conditioner compressor from 
    undesirable on/off sequences.
4) After a 5-minute wait, the air conditioning should now be on.  Whenever the cooling 
    system is running, the “

ON

” icon will be flashing.

1) Check if the air conditioning system’s main switch is turned on, as it may have been 
    turned off.
2) Wait several minutes for the air conditioning system to activate.  If the air conditioning still 
    does not come on, check the wiring installation again.  (Refer to page 6).

RESET

If the thermostat shows an abnormal display or if you
wish to change the temperature scale (°C or °F), use a 
pointed object to press the RESET key.

HG

HG

HE

HE

RESET

UPM warrants this product, excluding battery, to be free from defects in the materials or workmanship, under normal use and 
service, for a period of one

year from the date of purchase by the consumer.

If, at any time during the warranty period, the product is defective or malfunctions, UPM shall repair or replace it (at UPM's 
discretion) within a reasonable period of time.

If the product is defective,
(i)       return it, with a dated proof of purchase, to the retailer from which you purchased it, or
(ii)      package it carefully, along with a dated proof of purchase and a short description of the malfunction, and mail it, postage 
          prepaid, to the following address:

               UPM Marketing Inc.
               Return Goods
               Unit 10B - 250 Shields Court
               Markham, Ontario
               L3R 9W7

This warranty does not cover removal or reinstallation costs.  This warranty shall not apply if it is shown by UPM that the defect or 
malfunction was caused by damage which occurred while the product was in the possession of the consumer.

UPM's sole responsibility shall be to repair or replace the product within the terms stated above.  UPM SHALL NOT BE LIABLE 
FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, 
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF 
THIS PRODUCT.  Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation 
may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY UPM MAKES ON THIS PRODUCT.  THE DURATION OF ANY IMPLIED 
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS 
HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY.  Some states do not allow limitations on how long an 
implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.

If you have any questions concerning this warranty, please write to:

               UPM Marketing Inc.
               Customer Service Department
               Unit 10B - 250 Shields Court
               Markham, Ontario
               L3R 9W7

Or call 1-888-GO-TO-UPM (1-888-468-6876), Monday to Friday, from 9:00am to 5:00pm eastern.

 (1)

 

TEMPERATURE DISPLAY

CURRENT TEMPERATURE MODE

LCD display

TEMPERATURE SETTING MODE

1
2

HEAT OR COOL MODE

SYSTEM “ON” INDICATOR

3
4
5
6

3

4

5

1

6

7

COOL

ON

HEAT

LOW BATTERY INDICATOR

CURRENT TEMPERATURE MODE

TEMPERATURE SETTING MODE

HEAT OR COOL MODE

SYSTEM “ON” INDICATOR

4
5
6
7

TEMPERATURE SCALE (

 or  F)

°C

°

2

TEMPERATURE SCALE (

 or  F)

°C

°

3

2

Reviews: