Uplus Lighting 7X45 COB PAR User Manual Download Page 9

 

5.Trouble Shooting

   

Following are a few common problems that may occur during operation. Here are some suggestions for 
easy troubleshooting: 
 

A. The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 
2.  Measure the mains voltage on the main connector. 
3.  Check the power on LED. 
 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and DMX 

polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on   

PCB of the unit or the previous one. 

4.  Try to use another DMX controller. 

5.  Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or 

interference to DMX interface circuit. 

C. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor

’s drive IC on the PCB might be out of condition 

 

6.Fixture Cleaning 

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. 

 Clean with soft cloth using normal glass cleaning fluid. 

 Always dry the parts carefully. 

 Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

 

 

 

 

Summary of Contents for 7X45 COB PAR

Page 1: ...User manual 7X45 COB PAR Please read the instructions carefully before use...

Page 2: ...hooting 9 6 Fixture Cleaning 9 STATEMENT The product has well capability and intact packing when leave factory All of the user should comply with warning item and manual any misuse cause of the damage...

Page 3: ...utes for the unit to cool down before replacing or serving the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskil...

Page 4: ...o mode Master Slave Sound active Construction Display Digital panel Data In Out socket 3 pin XLR sockets Protection Rating IP20 Features Good cooling system over heat protection Dimmer 0 100 smooth di...

Page 5: ...ue Instruction 1 A001 DMX address 001 512 address code B C increase or reduce the value 2 25ch CH address Channel selection 25CH 3CH 7CH B C increase or reduce the Channels 3 Tr00 running change 000 0...

Page 6: ...t 7 48 53 Build in effect 8 54 59 Build in effect 9 60 65 Build in effect 10 66 71 Build in effect 11 72 77 Build in effect 12 78 83 Build in effect 13 84 89 Build in effect 14 90 95 Build in effect 1...

Page 7: ...H15 G4 Dimmer 0 255 Green4 Dimmer Dark to Bright CH16 B4 Dimmer 0 255 Blue4 Dimmer Dark to Bright CH17 R5 Dimmer 0 255 Red5 Dimmer Dark to Bright CH18 G5 Dimmer 0 255 Green5 Dimmer Dark to Bright CH19...

Page 8: ...25 156 161 Build in effect 26 162 167 Build in effect 27 168 173 Build in effect 28 174 179 Build in effect 29 180 185 Build in effect 30 186 191 Build in effect 31 192 197 Build in effect 32 198 203...

Page 9: ...use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not worki...

Reviews: