1.Safety Instructions 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also 

receive this instruction booklet. 

Unpack and check carefully there is no transportation damage before using the unit. 

•Before operating, ensure that the voltage and frequency of power supply match the power requirements of the 

unit. 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

•The unit is for indoor use only. Use only in a dry location. 

•The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure 

that no ventilation slots are blocked. 

•Disconnect main power before replacement or servicing. 

•Make sure there are no flammable materials close to the unit while operating as it is fire hazard. 

•Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always by taking its 

base. 

•Maximum ambient temperature is Ta: 40

. DO NOT operate it where the temperature is higher than this Unit 

surface temperature may reach up to 85

. DO NOT touch the housing bare-hand during its operation. Turn off 

the power and allow about 15 minutes for the unit to cool down before replacing or serving. 

•the event of serious operating problem, stop using the unit immediately.Never try to repair the unit by yourself. 

Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest 

authorized technical assistance center. Always use the same type spare parts. 

•DO NOT touch any wire during operation as high voltage might be causing electric shock. 

Warning: 

•To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. 

•The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. 

Caution: 

•There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any repairs yourself. 

In the unlikely event your unit may require service, please contact your nearest dealer. 

Installation: 

•The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to 

avoid vibration and slipping while operating. And make sure that the structure to which you are attaching the unit 

is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can 

hold 12 times of the weight of the unit when installing the fixture. 

The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of 

people. 

 

 

 

 

 

Summary of Contents for 300 MZ-SPOT PR

Page 1: ... Manual zoom 15 50 User manual 300 MZ SPOT PR Please read the instructions carefully before use ...

Page 2: ...n 8 8 LUX Date 8 9 Trouble Shooting 9 10 Fixture Cleaning 9 STATEMENT The product has well capability and intact packing when leave factory All of the user should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual ...

Page 3: ...nutes for the unit to cool down before replacing or serving the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts DO NOT touch any wire during operation as high volt...

Page 4: ...W Optics Zooming Scale 15 50 Manual zoom Soft and even field of light Features House Material Aluminum Alloy House Color Black Strobe 1 25times sec Control Control System DMX Auto run and Master Slave Manual zoom 1 3CH Working Environment Environment Temperature 30 C 40 C Cooling system No noise fan of Pccooler IP Grade IP20 Package Dimensions 397 D 211 W 378 H mm Net weight 8 5kgs Gross weight 11...

Page 5: ...d operate the fixture with following instructions Meanwhile please keep this manual well for future needs The 300 MZ SPOT PR is made of a new type of high temperature strength of cast aluminum casing with nice outlook The fixture is designed and manufactured strictly following CE RoHS standards complying with international standard DMX512 protocol It s available independently controlled and linkab...

Page 6: ...rst list is the main menu press MENU to exchange the second list is submenu press ENTER to get in or exchange If the menu include the decimal point that s the data and it can be set by the Key of Up Down Key operation Key of MENU Press it and can save the data If it s the main menu it will exchange to next main menu If it s the submenu it will back to main menu Key of ENTER Press it and can save t...

Page 7: ...TER save and change No vice menu diSP display ENTER reverse the display set to show reverse display No vice menu rESt reset ENTER enter the interface of key the password is UP DONW UP DOWN return Initial State return Initial State 6 DMX Channels Model CH3 channel data function Mark 1 0 255 dimmer 2 0 10 default delay of dimmer 11 15 no dimmer 16 255 Choose delay of dimmer 16 is the shortest delay ...

Page 8: ...8 7 Dimension Size of the fixture 379 D 211 W 378 H mm 8 LUX Date ...

Page 9: ... use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 10 Fixture Cleaning The cleaning of internal and ex...