background image

 

1.Safety Instructions 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 

that they also receive this instruction booklet. 

Unpack and check carefully there is no transportation damage before using the unit. 

•Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit. 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

•The unit is for indoor use only. Use only in a dry location. 

•The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 

surfaces. Be sure that no ventilation slots are blocked. 

•Disconnect main power before replacement or servicing. 

•Make sure there are no flammable materials close to the unit while operating as it is fire hazard. 

•Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always 

by taking its base. 

•Maximum ambient temperature is Ta: 40

. DO NOT operate it where the temperature is higher 

than this Unit surface temperature may reach up to 85

. DO NOT touch the housing bare-hand 

during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before 

replacing or serving. 

•the event of serious operating problem, stop using the unit immediately.Never try to repair the unit 

by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 

contact the nearest authorized technical assistance center. Always use the same type spare parts. 

•DO NOT touch any wire during operation as high voltage might be causing electric shock. 

Warning: 

•To prevent or reduce the risk of electrical shock or fire, do not expose the unit to

 

rain or moisture. 

•The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. 

Caution: 

•There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any 

repairs yourself. In the unlikely event your unit may require service, please contact your nearest 

dealer. 

Installation: 

•The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is 

Summary of Contents for 200 LED BSW

Page 1: ...User manual 200 LED BSW Please read the instructions carefully before use ...

Page 2: ...rouble Shooting 10 7 Fixture Cleaning 10 STATEMENT The product has well capability and intact packing when leave factory All of the user should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual ...

Page 3: ...ure is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried...

Page 4: ...fespan 50000 hours Operating mode DMX512 Auto Sound active Master slave Channel mode 18 DMX512 Channel Pan 540 16bit Electric correction Tilt 270 16bit Electric correction Color wheel 9 colors open with rainbow effect Gobo wheel 10 gobos open with rotation and running water effect Rotation gobo wheel 7 gobos open Prism 4 facet prism with bi direction rotating 0 100 linear dimming fit advanced iris...

Page 5: ...Menu Third Menu Forth Menu Settings Dmx Address 1 512 Fixture Set Dmx Mode STD EXT Run Mode DMX Host Pan Inverse Close Open Tilt Inverse Close Open Display Language CH EN Display Flip Close Open Display Mode Show 60s Reset XY Reset Cance Run Motor Reset Cance Run All Reset Cance Run Factory Cance Run Info Time Current Time xxxH Show Time xxxH Power Count xxx Sensor xxxxxx Software Version Panel Vx...

Page 6: ...nFine 0 255 Tilt 0 255 TiltFine 0 255 Factory Password 0 255 Pan 0 255 Tilt 0 255 Iris 0 255 Color 0 255 RotGobo 0 255 Gobo Rot 0 255 Fix Gobo 0 255 Frost 0 255 Color7 0 255 Effect 0 255 Prism 0 255 PrismRot 0 255 Zoom 0 255 Focus 0 255 4 DMX Channels ...

Page 7: ...rclockwise from slow to fast 9 0 4 Fixed gobo blank 5 54 10 fixed patterns every 5 numbers correspond to a pattern 55 154 10 fixed patterns jitter fast to slow every 10 numbers correspond to a pattern 155 204 Flowing in a clockwise pattern from fast to slow 205 205 Stop 206 255 Color flow counterclockwise from slow to fast 10 0 79 Rotary gobo 7 rotating patterns blank every 10 numbers correspond t...

Page 8: ...ern rotates clockwise from fast to slow 191 192 Stop 193 255 The pattern turns counterclockwise from slow to fast 14 0 127 Frost white 128 255 Frost 15 0 255 Zoom 0 100 linear Zoom 16 0 255 enlarge 0 100 linear Enlarge 17 0 50 Macro function No 51 100 System self check 101 150 Auto run 1 151 200 Auto run 2 201 255 Sound 18 0 250 No 251 255 Reset hold for 5 seconds to take effect 5 Dimension ...

Page 9: ...9 ...

Page 10: ...o use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Fixture Cleaning The cleaning of internal and ex...

Reviews: