Figure 4: Wiring example for voltage trip
Voltage Trip
- Inputs 2, 3, and 4 (and 1 if set for standard input) can be tripped by applying 12
V to the + input and 0 V to the - input. A signal must be continuously present for 500 ms.
Figure 5: Wiring example for open collector trip
Open Collector
- Inputs 2, 3 and 4 (and 1 if set for standard input) can be tripped by applying
12 V to the + input and the Open Collector output of the panel to the - input. A signal must be
continuously present for 500 ms.
Outputs
- Outputs 1 and 2 are dry contact relays rated for a maximum of 1 A at 24 VDC, and
are in the normally open condition. The outputs can be used to control other devices at the
installation site.
Power Supply
- The customer-supplied 12 VDC, 2 A rated power supply must be connected
to the unit at the 12 V terminal block connector. Terminate the positive voltage from the power
source to the “+” connector of the unit and terminate the ground of the power source to the “-”
connector. The power supply
must
be capable of delivering at least
2 A
.
Serial Interface
- The Module’s six-pin connector provides for network retransmission of
user-defined data packets via the built-in RS-232 port. You can purchase this 3-foot long cable
(Part No. 00-25540-300) which terminates in a DB9 connector.
Parts required to use the interface include:
Molex -
50-57-9406 - 2.54mm (.100") Pitch SL(tm) Crimp Housing, Single
Row, Version G, Positive Latch, 6 Circuits
Molex -
16-02-0103 - SL(tm) Crimp Terminal 70058, 22-24 AWG, Bag Selective
Gold (Au)
INPUT
–
INPUT
+
+
12 V
OUTPUT
From Panel