background image

 

 

 

 

 

LEDs Indication 

 

 

LED:

 

Off

: System disarmed 

Green

 : System armed  

Flashing

 

red

 : Alarm  

 

 
'OK'

 LED:

  

Green

: Power OK  

Yellow

: System trouble 

Flashing

 

green

: Open zone 

Flashing yellow

:  (Slow) Low 

battery, (Fast) AC loss 

 

Edit/Delete User Code 

1.

 

 From the main display press 

2.

 

 Enter master code (Default code 1234) 

3.

 

 Select [4] User Code and press 

 

 

4.

 

Select a user and press 

 

5.

 

 Select [1] Edit Code.  

6.

 

 Edit the user code or enter 0000 to  

delete 

7.

 

 Press 

 

Bypass / Unbypass a zone 

1.

 

 

Go to the main display and press 

2.

 

 Insert master code (default code '1234')

 

 

3.

 

On the Main menu, press [21] 

4.

 

 Select a zone and press 

 to toggle 

5.

 

 To save the status, press  

 

SMS Control Commands 

Controlling the System through SMS 
Command Code Numbers: 

120

: Disarm 

121

: Full arm 

122

: Part arm/Partition 1 arm 

200

: System arm status

 

 

123

: Perimeter arm/Partition 2 arm 

128

: Disarm partition 1 

129

: Disarm partition 2 

0XX

: HA unit XX off 

1XX

: HA unit XX on 

030

: PGM off 

130

: PGM on

 

SMS Structure: [Free text  - Up to 43 characters][#][User Code][Command] 

Example: DISARM#1234120

 

 

 