TECHNICAL
GUIDE 

TECHNICAL
GUIDE 

DESCRIPTION

The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.

FEATURES

• Small Footprint

 - Extremely lightweight with a compact foot-

print, it is a perfect fit for any application.

Quality Condenser Coils -

 The coil is constructed of alumi-

num microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency. 

Coil Protection

 - Coils are protected from damage by a slot-

ted, stamped steel coil guard and secondary polymer mesh.

Optional Factory E-Coat - 

Available ElectroFin® coated coil

on select models.

Protected Compressor -

 Compressors are protected inter-

nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high pressure switch.  A
factory installed liquid line filter-drier further protects the
compressor against moisture and debris.

Environmentally Friendly Refrigerant - 

The next genera-

tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.

Durable Finish -

 An automotive quality finish provides the

ultimate protection from harmful UV rays and rust-creep,
ensuring a long-lasting, high quality apprearance. A powder
paint top coat is applied over a baked on primer using a gal-
vanized, zinc coated steel base material.

Lower Installed Cost -

 Installation time and costs are

reduced by easy power and control wiring connections.  The
unit is factory charged for a 15-foot lineset.  The small base
dimension means less space is required on the ground or
roof.

Top Discharge -

 Warm air from the top mounted fan is

blown up, away from the structure and any landscaping.
This allows compact location on multi-unit applications.

Low Operating Sound Levels -

 The upward air flow carries

the normal operating noise away from the living area.  The
rigid top panel effectively isolates any motor sound.  Isolator
mounted compressor and the condenser coil muffle the nor-
mal fan motor and compressor operating sounds.

Low Maintenance -

 Long life, permanently lubricated motor-

bearings need no annual servicing.

Easy Service Access -

 Fully exposed refrigerant connec-

tions and a single panel covering the electrical controls make
for easy servicing of the unit.

Secured Service Valves -

 Secured, re-usable service

valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging. 

Agency Listed

 

-

 Safety certified by CSA to UL 1995 / CSA

22.2.  Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.

Summary of Contents for RAC13J30 THRU 60

Page 1: ...witch A factory installed liquid line filter drier further protects the compressor against moisture and debris Environmentally Friendly Refrigerant The next genera tion refrigerant R 410A delivers environmentally friendly per formance with zero ozone depletion Durable Finish An automotive quality finish provides the ultimate protection from harmful UV rays and rust creep ensuring a long lasting hi...

Page 2: ...minal CFM 2050 3200 3050 2950 3400 Coil Face Area Sq Ft 9 60 13 07 14 16 14 16 18 68 Rows Deep 1 1 1 1 1 Fins Inch 23 23 23 23 23 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 7 8 7 8 7 8 Unit Charge Lbs Oz 4 3 14 4 9 4 10 4 9 5 8 Charge Per Foot Oz 0 62 0 62 0 67 0 67 0 67 Operating Weight Lbs 131 145 164 173 220 Models with E on the end of the m...

Page 3: ...31 E RAC13J484S31 E RAC13J604S31 E Required Orifice or TXV 1 2 1 For applications requiring a TXV use S1 1TVM series kit 2 Approved orifice s shipped with outdoor unit 0 061 4F1 0 065 4G1 0 073 4G1 0 073 4H1 0 084 4J1 Indoor Unit 3 4 5 3 Systems matched with furnaces or air handlers not equipped with blower off delays may require blower Time Delay Kit S1 2FD06700224 4 PC coils cannot be used in do...

Page 4: ...MX16C 21 0 FC MC43C 1365 42 0 30 2 14 25 12 00 MX16C 21 0 FC MC48C 1390 42 0 30 2 14 25 12 00 MX16C 21 0 FC60C 1420 42 0 30 0 14 00 12 00 MX20D 24 5 FC MC48D 1415 42 0 30 2 14 25 12 00 MX20D 24 5 FC MC60D 1470 42 0 30 8 14 25 12 00 MX20D 24 5 FC MC62D 1470 42 0 31 6 14 50 12 25 MX20D 24 5 FC64D 1470 42 0 31 6 14 75 12 50 RAC13J484S31 E RFCX48DE 24 5 1600 47 0 34 6 13 75 11 50 RFCX48DP 24 5 1610 48...

Page 5: ...11 00 UC60 21 0 24 5 1400 1800 1600 48 0 34 4 13 00 11 00 RAC13J604S31 E FC MC PC60 21 0 24 5 1600 2000 1800 55 0 39 1 13 00 11 00 FC MC62 24 5 1600 2000 1800 55 5 40 1 13 00 11 00 FC64 24 5 1600 2000 1800 57 5 42 1 13 50 11 25 UC60 21 0 24 5 1600 2000 1600 53 5 37 0 13 00 10 75 1 Requires a S1 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one COOLING CAPACITY With High ...

Page 6: ... 21 0 FC MC PC48D 1475 42 0 31 0 14 25 12 00 R L CE20 21 0 FC MC PC60D 1485 42 0 31 0 14 00 12 00 R L CE20 21 0 FC MC62D 1485 42 0 31 6 14 25 12 00 R L CE20 21 0 FC PC60C 1485 42 0 31 0 14 00 12 00 R L CE20 21 0 FC64D 1485 42 0 31 8 14 50 12 25 R L CE20 21 0 UC48C 1475 42 0 31 0 14 00 12 00 R L CE20 21 0 UC60C 1485 42 0 31 0 13 75 11 75 R 9 BE12 17 5 FC MC PC43B 1270 41 5 29 0 13 50 11 50 R 9 CE16...

Page 7: ... E R L CE16 21 0 FC MC PC48C 1600 48 0 34 4 13 30 11 00 R L CE16 21 0 FC PC60C 1605 48 0 34 6 13 30 11 00 R L CE20 21 0 FC MC PC48C 1660 48 0 34 4 13 20 11 00 R L CE20 21 0 FC MC PC60D 1595 48 0 34 8 13 30 11 00 R 9 CE16 21 0 FC MC PC48C 1565 48 0 34 8 13 10 11 00 R 9 CE16 21 0 FC PC60C 1575 47 0 34 6 13 10 11 00 R 9 CE16 21 0 UC60C 1575 47 0 34 6 13 10 11 00 R 9 CE20 21 0 FC MC PC48C 1615 48 0 34...

Page 8: ...CK SEAL OPENING S WITH PERMAGUM OR EQUIVALENT NOTES ALL OUTDOOR WIRING MUST BE WEATHERPROOF MINIMUM 24 UNIT TO UNIT CLEARANCE ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC AND OR LOCAL CODES POWER WIRING CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BL...

Page 9: ...2 72 2 71 2 78 2 84 2 84 2 83 2 81 2 64 2 94 2 95 2 94 2 92 2 49 3 04 105 T C 21 8 23 1 21 7 25 2 27 9 23 4 24 6 22 6 25 8 28 0 25 0 26 1 23 5 26 4 28 1 S C 20 9 21 1 17 4 17 7 13 4 22 4 22 2 19 3 19 3 14 5 24 0 23 3 21 3 20 8 15 7 KW 2 91 3 02 2 88 2 96 3 04 3 03 3 08 2 99 2 90 3 14 3 15 3 14 3 10 2 84 3 24 115 T C 19 8 21 1 19 1 22 2 25 0 21 2 22 4 19 9 22 7 25 0 22 6 23 6 20 8 23 2 25 0 S C 19 ...

Page 10: ...5 3 22 3 27 3 32 105 T C 28 0 28 9 27 8 31 1 34 3 28 9 29 9 28 5 31 6 34 6 29 9 30 9 29 2 32 0 34 9 S C 26 3 26 2 22 0 21 9 16 6 27 4 27 8 23 8 23 8 17 7 28 5 29 4 25 6 25 7 18 9 KW 3 25 3 25 3 23 3 30 3 37 3 36 3 36 3 33 3 39 3 47 3 47 3 47 3 43 3 49 3 56 115 T C 25 0 25 9 24 3 27 8 31 7 25 7 26 9 25 1 28 2 32 0 26 4 27 9 25 9 28 7 32 3 S C 23 7 23 9 20 3 20 8 15 8 24 4 25 2 21 8 22 8 17 0 25 2 2...

Page 11: ... 3 52 95 T C 35 8 35 9 36 3 40 9 44 8 37 5 36 9 37 3 41 5 45 2 39 2 37 9 38 2 42 1 45 6 S C 35 4 33 0 27 6 27 7 21 7 37 1 35 3 30 0 29 8 23 0 38 8 37 6 32 3 31 9 24 4 KW 3 67 3 68 3 68 3 76 3 82 3 71 3 70 3 70 3 77 3 83 3 75 3 72 3 72 3 79 3 84 105 T C 33 1 33 1 32 6 37 0 41 6 34 7 34 2 33 5 37 6 42 0 36 3 35 4 34 4 38 2 42 4 S C 32 7 31 0 26 3 26 4 20 7 34 3 33 1 28 4 28 6 22 1 35 9 35 2 30 5 30 ...

Page 12: ... R L CE20 UC60C 1 01 1 04 0 95 R 9 BE12 FC MC PC43B 1 00 0 97 0 96 R 9 CE16 FC MC PC43C 1 01 1 01 0 97 R 9 CE16 FC MC PC48C 1 01 1 02 0 95 R 9 CE16 FC MC PC48D 1 01 1 02 0 95 R 9 CE16 FC MC PC60D 1 01 1 01 0 97 R 9 CE16 FC MC62D 1 01 1 03 0 95 R 9 CE16 FC PC60C 1 01 1 01 0 97 R 9 CE16 FC64D 1 01 1 03 0 93 R 9 CE16 UC48C 1 01 1 02 0 95 R 9 CE16 UC60C 1 01 1 01 0 97 R 9 CE20 FC MC PC43C 1 01 1 02 0 ...

Page 13: ... 32 7 32 4 23 9 42 1 42 3 34 8 34 6 25 0 44 2 45 0 36 9 36 7 26 1 KW 4 22 4 22 4 22 4 34 4 46 4 26 4 26 4 24 4 36 4 47 4 30 4 30 4 27 4 39 4 49 105 T C 39 8 39 3 37 3 42 4 43 5 41 6 41 1 38 4 43 4 44 0 43 4 42 8 39 5 44 3 44 5 S C 36 8 36 7 30 7 30 7 22 7 38 6 39 0 32 7 32 8 23 7 40 5 41 2 34 7 34 9 24 8 KW 4 52 4 52 4 49 4 62 4 77 4 57 4 57 4 52 4 65 4 79 4 61 4 61 4 55 4 67 4 81 115 T C 36 4 35 ...

Page 14: ...2 3 52 1 56 4 59 2 52 0 53 1 52 8 57 2 59 8 S C 49 6 45 7 38 8 37 6 29 1 50 8 47 7 40 7 38 9 30 1 52 0 49 8 42 5 40 3 31 0 KW 4 38 4 39 4 39 4 44 4 49 4 39 4 40 4 40 4 46 4 50 4 41 4 41 4 41 4 47 4 51 95 T C 48 8 50 2 49 8 54 2 56 9 50 0 51 1 50 6 55 0 57 5 51 3 51 9 51 4 55 8 58 2 S C 48 7 46 1 38 8 37 6 28 5 50 0 48 2 40 7 39 1 29 6 51 3 50 4 42 6 40 6 30 6 KW 4 91 4 92 4 92 4 99 5 03 4 92 4 93 ...

Reviews: