UPG FC9T-DH User Manual Download Page 16

Subject to change without notice. Printed in U.S.A.

272360-UUM-A-0407

Copyright

 ©

 by York International Corp 2007. All rights reserved.

Supersedes:  167802-UUM-B-0806

Unitary

5005 Norman

Products

York

OK

Group

Drive

73069

Limited Warranty

UPG warrants this product to be free from defects in factory workmanship and material under normal use and service and will, at its option, repair or replace
any parts that prove to have such defects according to the terms outlined on this warranty. This warranty covers only the equipment described by the Product
Model Number and Serial Number listed on the Warranty Registration Card.
UPG warrants the primary heat exchangers in the product to be free from defects in factory workmanship and material under normal use and service and will at
its option, repair or furnish a replacement heat exchanger, either new or reconditioned, that meets the intended fit, use and function of the original heat
exchanger for any heat exchanger furnished by UPG which proves to have such defects within the duration of warranty coverage. Alternatively, UPG may, at its
option, extend a replacement allowance to be applied toward the purchase of a new furnace or packaged unit marketed by UPG. The exact amount of the
allowance will be determined at the discretion of UPG, based upon current market conditions, but in no case shall this allowance exceed thirty (30) percent of
the original consumer purchase price of the furnace, excluding such items as ductwork, wiring, piping and installation costs. UPG shall have no responsibility
hereunder for installation, shipping, handling or other charges except as specifically provided herein.
For your benefit and protection, return the Warranty Registration Card to UPG promptly after installation. This will initiate the warranty period and allow us to
contact you, should it become necessary. In the absence of a recorded Warranty Registration Card, the warranty period will begin upon product shipment from
UPG.

This warranty extends only to the original consumer purchaser and is non-transferable. For this warranty to apply, the product must be installed according to
UPG recommendations and specifications, and in accordance with all local, state, and national codes; and the product must not be removed from its place of
original installation. The warranty period for repair or replacement parts provided hereunder shall not extend beyond the warranty period stated on the reverse
side of this warranty.

UPG strongly recommends regular periodic preventative maintenance on this equipment. The person most familiar with the equipment in your HVAC system is
a UPG dealer. The UPG dealer can ensure your maintenance program meets the conditions of the "UPG Warranty", maximize the efficiency of the equipment,
and service your unit within the mandated guidelines with regard to unlawful discharge of refrigerants into the atmosphere.
This warranty applies only to products installed in the United States and Canada.

EXCLUSIONS

This warranty does not cover any:
1.

Shipping, labor, or material charges.

2.

Damages resulting from transportation, installation, or servicing.

3.

Damages resulting from accident, abuse, fire, flood, alteration, or acts of God (tampering, altering, defacing or removing the product serial number will
serve to void this warranty).

4.

Damages resulting from use of the product in a corrosive atmosphere.

5.

Damages resulting from inadequacy or interruption of electrical service or fuel supply, improper voltage conditions, blown fuses, or other like damages.

6.

Cleaning or replacement of filters.

7.

Damages resulting from failure to properly and regularly clean air and/or water side of condenser and evaporator.

8.

Damages resulting from: (I) freezing of condenser water or condensate; (II) inadequate or interrupted water supply; (III) use of corrosive water; (IV) fouling
or restriction of the water circuit by foreign material or like causes.

9.

Damages resulting from operation with inadequate supply of air or water.

10.

Damages resulting from use of components or accessories not approved by UPG (vent dampers, etc.).

11.

Increase in fuel or electric cost.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABIL-
ITY AND FITNESS FOR A PARTICULAR PURPOSE.

SOME STATES DO NOT ALLOW THE DISCLAIMER OF IMPLIED WARRANTY, SO THAT THE ABOVE DISCLAIMER MAY NOT APPLY TO YOU.

SOME STATES ALLOW ONLY A PARTIAL LIMITATION ON IMPLIED WARRANTIES TO LIMIT THE DURATION OF IMPLIED WARRANTIES TO THE DURA-
TION OF THE EXPRESS WARRANTY. IN SUCH STATES, THE DURATION OF IMPLIED WARRANTIES IS HEREBY EXPRESSLY LIMITED TO THE DURA-
TION OF THE EXPRESS WARRANTY ON THE FACE HEREOF.

IN NO EVENT, WHETHER AS A RESULT OF BREACH OF WARRANTY OR CONTRACT, TORT (INCLUDING NEGLIGENCE) STRICT LIABILITY OR OTH-
ERWISE, SHALL UPG BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF USE OF
THE EQUIPMENT OR ASSOCIATED EQUIPMENT, LOST REVENUES OR PROFITS, COST OF SUBSTITUTE EQUIPMENT OR COST OF FUEL OR ELEC-
TRICITY. THE ABOVE LIMITATIONS SHALL INURE TO THE BENEFIT OF UPG'S SUPPLIERS AND SUBCONTRACTORS. THE ABOVE LIMITATION ON
CONSEQUENTIAL DAMAGES SHALL NOT APPLY TO INJURIES TO PERSONS IN THE CASE OF CONSUMER GOODS.

SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR FOR STRICT
LIABILITY IN TORT, SO THAT THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU.

UPG DOES NOT ASSUME, OR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR UPG, ANY OTHER LIABILITY FOR THE SALE OF THIS PRODUCT.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

For Owner's Information:

FURNACE TYPE

HEAT EXCHANGER

PARTS

Residential Applications

Non-Residential 

Applications

Original Owner

Subsequent Owner

90%

PT9 / FC9T / FL9T

Lifetime

20

10

5

PRODUCT MODEL. NO. ____________________ INSTALLATION DATE ______________________________
UNIT SERIAL NO. _________________________ INSTALLING DEALER ______________________________

Summary of Contents for FC9T-DH

Page 1: ...sary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone including cell phone in your building Le...

Page 2: ...e furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Examine the furnace casing for obvious signs of deterioration 6 Examine the burner flames to make sure they are in good adjust ment Refer to the pictorial sketch shown in Figure 2 as a compari son ...

Page 3: ...ructions 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 7 Move gas control switch to t...

Page 4: ...hed to the cas ing of the furnace or placed in the return air duct You can gain access to the filter by pulling on the door or unscrewing the retaining screw then slide the filter s out of its channel Replace throw away filter s with the same size new filter s Throw away filter s may be replaced with cleanable filter s at this time Cleanable filter s may be cleaned as described in the manufacturer...

Page 5: ...int 3 Remove the burner door and remove the burner box cover 4 Disconnect wires from flame sensor rollout switch and HSI igniter Remove igniter carefully as it is easily broken 5 Remove the screws that hold the burner box assembly to the vest panel and remove the assembly 6 Remove the vent pipe assembly vent blower and condensate pan 7 The heat exchanger is now exposed 8 With a long flexible wire ...

Page 6: ...e Satisfied The Thermostat opens the circuit between R and W1 Immediately the Gas Valve is de energized and Flame Rectifica tion is lost The Inducer Motor is de energized after a 15 second Post Purge and the Hum terminal is de energized The Fan Off Delay circuit is initiated The Delay time can be field set at 60 90 120 or 180 seconds It comes from the fac tory set at 60 seconds The Heat Low termin...

Page 7: ...r Check for proper gas flow 4 AMBER FLASHES The control board is recieving a Y signal from the thermostat without a G signal indicating improper thermostat wir ing 1 RED FLASH This indicates that flame was sensed when there was not a call for heat With this fault code the control will turn on both the inducer motor and supply air blower A gas valve that leaks through or is slow closing would typic...

Page 8: ...cludes a watchdog type circuit that will reset from a lockout condition after 60 minutes Operational faults 6 7 8 will be reset This provides protection to an unoccupied structure if a temporary condition exists causing a furnace malfunction An example would be a low incoming gas supply pressure preventing unit operation When the gas pressure is restored at some point the watchdog would restart th...

Page 9: ...NDUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC TRIAL FOR IGNITION 7 SEC INTER PURGE 60 SEC HSI WARM UP 27 SEC IGNITION DEACTIVATION PERIOD 3 SEC HEAT FAN DELAY ON 30 SEC BURN TIME POST PURGE 15 SEC HEAT FAN DELAY OFF SELECTABLE 60 90 120 180 SEC OFF O...

Page 10: ...Products Group SECTION III REPLACEMENT PARTS LIST 9 5 7 12 54 52 74 75 27 26 25 21 23 24 68 57 67 69 70 61 59 1 15 50 51 18 17 20 45 68 47 49 29 13 5 8 35 52 4 2 41 42 43 46 44 16 14 3 10 13 34 9 6 19 22 28 29 32 31 48 53 58 62 49 ...

Page 11: ...CTOR COMBUSTION BLWR 42 GASKET COMBUSTION BLOWER 43 GASKET CONDENSATE PAN 44 GASKET CONDENSING COIL 45 GASKET GAS CONTROLS 46 GASKET UPPER COND PAN 2 Req d 47 GASKET COMBUSTION AIR TRANSITION 48 GROMMET MANIFOLD SEAL 49 PLUG WINDOW CLEAR 1 5 50 GROMMET MOTOR MOUNT 3 Req d 51 FERRULE MOTOR MOUNT 3 Req d 52 PAN CONDENSATE 53 ORIFICE BURNER Natural 45 54 TRAP CONDENSATE 55 WIRING DIAGRAM 56 HARNESS M...

Page 12: ...ENT TERMINATION KIT 2 ALL MODELS 1CB0317 COMBUSTIBLE FLOOR BASE 17 1 2 CABINET 1CB0321 21 CABINET 1CB0324 24 1 2 CABINET 1TK0917 COIL TRANSITION KIT 17 1 2 CABINET 1TK0921 21 CABINET 1TK0924 24 1 2 CABINET REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete parts list refer to the contact information below Visit our website at www source1parts com for the follow...

Page 13: ...272360 UUM A 0407 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram ...

Page 14: ...272360 UUM A 0407 14 Unitary Products Group NOTES ...

Page 15: ...272360 UUM A 0407 Unitary Products Group 15 NOTES ...

Page 16: ...nly to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing 3 Damages resulting from accident abuse fire flood alteration or acts of God tampering altering defacing or removing the product serial number will serve to void this warranty 4 Damages resulting...

Reviews: