Photometric Diagram

Spectral Distribution

Polar intensity diagram

Polar intensity diagram

Polar intensity diagram

Polar intensity diagram

Beam diagram

Beam diagram

Beam diagram

Beam diagram

Cartesian intensity diagram

Cartesian intensity diagram

Cartesian intensity diagram

Cartesian intensity diagram

UNIT: cd

AVERAGE BEAM ANGLE(50%): 131.2 DEG

-/+180

-120

-90

-30

120

90

30

0

200

400

600

800

1000

0

UNIT: cd

AVERAGE BEAM ANGLE(50%): 131.0 DEG

-/+180

-120

-90

-30

120

90

30

0

300

600

900

1200

1500

0

UNIT: cd

AVERAGE BEAM ANGLE(50%): 130.7 DEG

-/+180

-120

-90

-30

120

90

30

0

300

600

900

1200

1500

0

UNIT: cd

AVERAGE BEAM ANGLE(50%): 131.4 DEG

-/+180

-120

-90

-30

120

90

30

0

300

600

900

1200

1500

0

Planar Illuminance Curve

Distance(m)

MH=10m

E(LX)

10

9

8

7

6

5

4

3

2

1

0

C0/180

C90/270

-25

-20

-15

-10

-5

0

5

10

15

20

25

Planar Illuminance Curve

Distance(m)

MH=10m

E(LX)

15.0

13.5

12.0

10.5

9.0

7.5

6.0

4.5

3.0

1.5

0

C0/180

C90/270

-25

-20

-15

-10

-5

0

5

10

15

20

25

Planar Illuminance Curve

Distance(m)

MH=10m

E(LX)

15.0

13.5

12.0

10.5

9.0

7.5

6.0

4.5

3.0

1.5

0

C0/180

C90/270

-25

-20

-15

-10

-5

0

5

10

15

20

25

Planar Illuminance Curve

Distance(m)

MH=10m

E(LX)

15.0

13.5

12.0

10.5

9.0

7.5

6.0

4.5

3.0

1.5

0

C0/180

C90/270

-25

-20

-15

-10

-5

0

5

10

15

20

25

Height     Eavg, Emax     Angle: 110.70deg     Diameter

Note: The Curves indicate the illuminated area and the average 

          illumination when the Luminaire is at different distance.

Flux out: 2043 lm

Height     Eavg, Emax     Angle: 109.14deg     Diameter

Note: The Curves indicate the illuminated area and the average 

          illumination when the Luminaire is at different distance.

Flux out: 2274 lm

Height     Eavg, Emax     Angle: 110.02deg     Diameter

Note: The Curves indicate the illuminated area and the average 

          illumination when the Luminaire is at different distance.

Flux out: 2270 lm

Height     Eavg, Emax     Angle: 109.89deg     Diameter

Note: The Curves indicate the illuminated area and the average 

          illumination when the Luminaire is at different distance.

Flux out: 1098 lm

380

500

600

700

800

380

500

600

700

800

380

500

600

700

800

380

500

600

700

800

Wavelength(nm)

Wavelength(nm)

Wavelength(nm)

Wavelength(nm)

Max=7798  [1.0=20000]

Max=7530  [1.0=20000]

Max=5808  [1.0=20000]

Max=9472  [1.0=20000]

Spectrum

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

Spectrum

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

Spectrum

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

Spectrum

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

0.37 SDCM  F4000K

x=0.3801  y=0.3808

5700K

4000K

3000K

5000K

5700K

3000K

4000K

5000K

www.upshine.com   [email protected]

5.69 SDCM  F5700K

x=0.3234  y=0.3444

3.20 SDCM  F3000K

x=0.4427  y=0.3996

1.25 SDCM F5000K

x=0.3483  y=0.3619

Summary of Contents for UP-DB18-1600-40W

Page 1: ...Technical Application Guide for UP SHINE LED Batten Light UP DB18 1600 40W ...

Page 2: ...luminate the ceiling 5 Colour rendering index CRI Ra 80 6 Impact protection IK10 7 LED service life approx 50 000 hours L80 B10 25 C 8 End caps made of shockproof polycarbonate PC 9 Extruded PC opal diffuser with inner prisms and UV resistant providing homogenous light distribution 10 Flexible installation through sliding mounting bracket Ideal for luminaire replacement 11 Providing through wiring...

Page 3: ...Current output tolerance 5 Short circuit protection PASS Over voltage protection PASS Over temperature protection PASS THD 20 Withstand voltage Technical Specifications Model Voltage Power Power Factor Lumen 5 Beam angle CCT Lifespan CRI Dimmable Dimension UP DB18 1600 40W AC100 277V 40W 0 9 4080 140o 3000K 50000h 80 No 1600 78 53 5mm UP DB18 1600 40W AC100 277V 40W 0 9 4520 140o 4000K 50000h 80 N...

Page 4: ...0 270 25 20 15 10 5 0 5 10 15 20 25 Height Eavg Emax Angle 110 70deg Diameter Note The Curves indicate the illuminated area and the average illumination when the Luminaire is at different distance Flux out 2043 lm Height Eavg Emax Angle 109 14deg Diameter Note The Curves indicate the illuminated area and the average illumination when the Luminaire is at different distance Flux out 2274 lm Height E...

Page 5: ...19 10 16 37 10 Time Driver lifetime LED light decay rate 90000 80000 70000 60000 50000 40000 30000 20000 10000 0 65o C 75o C 85o C 95o C 105o C Lifetime hours Capacitor Tc o C Driver Lifetime LED Light Decay Rate Luminous Flux FLUX U V 110 105 100 95 90 85 80 75 70 0 0040 0 0035 0 0030 0 0025 0 0020 0 0015 0 0010 0 0005 0 0000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 LifeTime hours Tem...

Page 6: ...ing the clips on the ceiling Open the end cap put the wires through the hole connect the terminal block Brown to L Blue to N tighten the end cap to prevent the water into the lamp Knock 2pcs plastic anchors into ceiling fix the wire regulating device on ceiling Put the hook through metal plate embed the metal plate in the slot of the lamp body 100 130V 12 26 UP DB18 1600 40W 200 277V Linkable lumi...

Page 7: ...hone 86 755 2919 7389 Add 2nd building Dingfeng High Tech Zone Fuyuan 1st road Fu Yong Sub district Bao an Shenzhen China Step3 L N Step4 BLUE BROWN L N Adjust the length of suspending wires on same level turn on the light Hanging the lamp to the suspending wires Open the end cap put the wires through the hole connect the terminal block Brown to L Blue to N tighten the end cap to prevent the water...

Reviews: