NOTE! 

Equipment grounding shall be properly grounded through the specified 

grounding terminal.

 

2.2  

Starting Up the Device 

After  the  cables  are  connected,  connect  the  device  with  the  power  source,  and 
start up the device. Examine the device status according to Table 1-1. 

 

3

 

Logging In to and Out of the Device 

You can manage and maintain the device through the Web interface. 

Before you log into the device, verify that: 

 

The device is operating correctly. 

 

The network connection between the PC and the device is normal. 

 

The PC is installed with Microsoft Internet Explorer 7.0 or higher. 

 

The browser on the PC is not configured with the proxy server.  

The  default  IP  address  of  the  device  is  192.168.1.14,  the  subnet  mask  is 
255.255.255.0, and the default gateway is 192.168.1.1. 

For the first login, use 

admin

 

as the username and 123456 as password. 

To log into the Web interface: 

1.

 

Use the IE browser on your PC to visit the IP address of the device. 

2.

 

On the login page, enter your username and password to access the Web 

interface. 

You  can  select  a  menu  item  on  the  Web  interface  and  select  a  tab  to  enter  the 
corresponding configuration page.  

For information about the initial configuration and other parameter configurations, 

Summary of Contents for DC550 E Series

Page 1: ...1 Video Decoders Quick Guide V1 00...

Page 2: ...is designed for remote video surveillance and can be widely applied in various real time surveillance applications for monitoring videos remotely in real time 1 1 Packing List Please check the items i...

Page 3: ...larm is present Off No alarm is present NET LED On A link to the Ethernet Interface is present Off No link to the Ethernet Interface is present No 1 9 LED DEC On The device is displaying video Off The...

Page 4: ...B 3 0 1 USB 3 0 interface for upgrading equipment RS485 1 Serial port used to interoperate with the connected device for example to transmit transparent channel data RJ 45 connector four wires support...

Page 5: ...ismantlement preventive seal from the device chassis cover without permission To open the chassis contact your dealer Otherwise we shall not be held liable for any consequence caused thereby 2 1 2 Che...

Page 6: ...ormal The PC is installed with Microsoft Internet Explorer 7 0 or higher The browser on the PC is not configured with the proxy server The default IP address of the device is 192 168 1 14 the subnet m...

Page 7: ...ng the Help menu For the first login you are recommended to change the default login password by selecting Change Password To log out of the device you can click the Exit menu and confirm your operati...

Page 8: ...egarding the product described in this manual Uniview asks you to fully understand and strictly abide by the applicable export laws and regulations worldwide Privacy Protection Reminder Uniview compli...

Page 9: ...s of profits and any other commercial damages or losses loss of data procurement of substitute goods or services property damage personal injury business interruption loss of business information or a...

Page 10: ...to disable UPnP if HTTP and TCP port mapping have been enabled manually on your router SNMP Disable SNMP if you do not use it If you do use it then SNMPv3 is recommended Multicast Multicast is intend...

Page 11: ...utlet with a protective earthing grounding connection Ground your device properly if the device is intended to be grounded Battery Use Caution When battery is used avoid High or low extreme temperatur...

Page 12: ...LVD EMC Directive This product complies with the European Low Voltage Directive 2014 35 EU and EMC Directive 2014 30 EU WEEE Directive 2012 19 EU The product this manual refers to is covered by the Wa...

Reviews: