background image

 
 
 

 

Electric Combi Boiler            
User Manual 

 

 

 

 

ÜNLÜSOY  

Yapı Malzemeleri Sanayi ve Ticaret Ltd. 

Pancar Organize Sanayi Bölgesi, 2. Etap No:2,  Torbalı – İZMİR/TURKEY  

Tel: +90 444 35 32, Fax: +90 232 469 2412 

www.unmak.com

 

 

 

Summary of Contents for UEK 12

Page 1: ...Electric Combi Boiler User Manual NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal ZM R TURKEY Tel 90 444 35 32 Fax 90 232 469 2412 www unmak com...

Page 2: ...Y PRECAUTIONS 4 ELECTRIC INSTALLATION INSTRUCTIONS 5 COMBI FEATURES 6 WARNINGS 6 CONTROL PANEL AND USER INTERFACE 8 START UP 9 TIMER AND CLOCK SETTINGS 10 CARE AND BOILER CLEANING 12 Regular checks 12...

Page 3: ...the boiler and in case of electric leakage for any reason to the body the combi is automatically deactivated by the leakage current relay The electric boiler water temperature is set on the electroni...

Page 4: ...nly be as much as the amount of equipment supplied in the appliance The energy required for domestic water will be taken from the energy of the device This product must be connected to the mains with...

Page 5: ...uld be no water leakage The connection of the phase and neutral inputs must be entered into the fuse and neutral terminal on the boiler as in the connection diagram Phase and neutral inputs should be...

Page 6: ...erms of circuit break time and temperature limits There is a maximum permissible cable length limitation in a line combination to be created for the current requirement voltage drop and cable cross se...

Page 7: ...ever all iron based components in the heating installation including installation pipes and radiators must be protected against corrosion Oxygen in the water is caused by oxidation of iron surfaces re...

Page 8: ...hroughout the installation Important Considerations for Heating Systems Connected to Old Installations In a long term heating system a protective layer black magnetite is formed on metal surfaces in c...

Page 9: ...Used to operate the device in winter mode When the button is pressed the lamp on it switches to winter mode Three way valve takes the position of winter It starts heating by gradually opening the heat...

Page 10: ...boiler water level and pressure check all connections and pipes for leaks Do not add water if the boiler is cold To operate in winter Press the button to set the desired temperature with the button T...

Page 11: ...off according to the temperature value at which the thermostat is set If the room thermostat is not used this input of the device must be bridged TIMER AND CLOCK SETTINGS To set the timer and clock t...

Page 12: ...the TIMER DEL button in the menu and press the button From the incoming screen select YES and press All timer set values will be deleted To operate timer If you have set timer times from the Timer men...

Page 13: ...he system before each working season we strongly recommend that you call our authorized service to check the device installation electrical connections Do not do any maintenance work without the help...

Page 14: ...r error domestic water The temperature sensor may be faulty or there may be a problem with the connections Check that the cable lugs are attached by disconnecting the power to the appliance Call servi...

Page 15: ...a g e 14 Electric Combination Boiler User Manual NL SOY YAPI MALZEMELER SANAY VE T CARET L M TED RKET zmir Pancar Organize Sanayi B lgesi 10 Cadde No 2 Torbal ZM R TURKEY Tel 90 444 35 32 www unmak co...