background image

Connections and controls

PLS-X5

Loop current

Monitor

-6 

Parametric MLC

In 1

In 2

In 3

Professional Loop System

0 +12 dB

Clip

System Diagnostics

-18

On

0

3

6

9 dB

100 500 1k 2k

Off

1.

1.

1.

2.

4.

5.

7.

6.

8. 9.

10.

1.  Input Level Control 
2.  Input Level LEDs 
3.  Parametric MLC Control
4.  Parametric MLC Knee Point Switch
5.  System Diagnostics Switch
6.  Loop Current Control 
7.  Loop Current LEDs
8.  Voltage Clipping/Peak LED
9.  Loop Monitor Jack
10.  Power LED
11.  Loop Terminals
12.  DC Supply Jack
13.  Monitor Speaker Connector 
14.  Auxiliary DC Power Output
15.  Remote Input Monitor Connector

16.  Remote Output Monitor Connector
17.  Monitor Volume Control
18. 

Input Power Amplifier (In Pow Amp)

19. 

Output Pre-amplifier (Out Pre Amp)+

20.  Input 3 

(Phoenix Screw Terminal/RCA)

21.  Input 2 

(Phoenix Screw Terminal)

22.  Speech Enhancement DIL Switch  

(Flat/Speech)

23.  50-100 V Line DIL Switch On/Off
24.  Override DIL Switch On/Off (Input 3)

25.  Input 1 

(Balanced XLR)

26.  Speech Enhancement DIL Switch  

(Flat/Speech)

27.  Line/Mic Sensitivity DIL Switch
28.  Phantom Power On/Off

DC+ 

In Pow

Amp

Input 2

Input 1

L

R

+ -

L

R

www.univox.eu

Flat / Speech

Override / OFF

Flat / Speech

Phantom / OFF

Monitor

Out Pre

Amp

+

PUSH

q

+

50-100 V / OFF

Line / Mic

Input 3

-

+

C

12.

11.

17.

13.

14.

15.

16.

18.

19.

20.

21.

28.

27.

26.

24.

23.

22.

25.

3

1.  Place the loop driver in a suitable location. There are three placement options for   

 

the PLS-X series drivers: 

● In a 19" rack 

 

● Hung on a vertical surface using the keyholes in the base of the unit

 

● On a flat level surface on the units rubber feet

 

Note

 

No ventilation space in the rack is required. When placed on flat surfaces the little space given 

 

by the rubber feet is sufficient.

 

2.  Connect the loop cable to the loop driver  

using the Loop Terminals (11) as shown in figure.

 

3.  Connect the power supply, first to the loop 

 

driver’s DC Supply Jack (12) and then to the  

wall outlet. The Blue ‘power On’ LED (10)  

will illuminate. 
4.  Turn System Diagnostics (5) on by sliding the switch to the right. The Input Level  

LEDs (2) will begin to blink. 
5.  Adjust the loop current. Depending on the adjusted current level, 1, 2, 3 or 4 out  

put current LEDs will blink in unison. 

6.  Set the current to achieve a field strength of the peaks to approximately -3 dB in 

 

the center of the loop. 

The system is functioning correctly and is ready for commissioning in accordance  

with the IEC performance standard IEC 60118-4. 
7.  Turn System Diagnostics (5) off, by sliding the switch to the left.

2-turn loop

1-turn loop

Single turn Loop

2-turn Loop using 
twin core cable

Default Settings

Front panel

 

All level controls are set to minimum  

(turned fully anti-clockwise).  

System Diagnostic (5) = Off (switch in left position). 

Parametric MLC (3,4)= 2 kHz (switch in right position).

Input 1

 

Flat/Speech; DOWN (= speech enhancement off) 

Line/Mic; DOWN  

Line/Mic; DOWN  

Phantom/off; UP (= phantom power off)

Input 2

 

Flat/Speech; DOWN (= speech enhancement off) 

50-100V/off; UP 

50-100V/off; UP 

Override/off; UP (= override off)

Rear panel

 

Monitor Control; Set fully anti-clockwise (factory default)  

Installation