Univox PLS-100 Installation Manual Download Page 2

UniVox

®

 PLS-100 Installation Guide

®

®

General planning and installation procedures

1. Preparations

a) If the loop cable is already planned, install according to the drawings. Then read clause 2.

b) If the loop cable is already planned and installed, read clause 2.

c) If the loop cable is to be planned and installed ”on site”, please read the following guidelines.

●  Use a 2x2.5mm² twin loop wire, for high fl exibility to the installer. If other loop wires are used, the amplifi er’s effi ciency 

may be affected. Recommended minimum loop wire area is described in the table at page 3.

●  If the space for the loop cable is limited, a fl at copper foil (Part No 861023) can be used as an alternative.
●  The fi eld strength can be reduced due to reinforced concrete and other metal structures. If so, the fi eld strength can be 

doubled (appr. 6dB) if 2 amplifi ers are used, one for each separate wire of the twin wire, or use a more powerful amplifi er 

as an alternative.

●  Do not place input cables close/parallel to the loop wire.
●  Do not place the loop wire close to and parallel with reinforcement iron or other metal structures. This will reduce the 

magnetic fi eld strength.

●  If the smallest distance in a loop exceeds 10 meters, please consider another loop confi guration, for example a fi gure-

eight loop or plan for a SLS System (see next paragraph).

●  Please be aware of the overspill effect. If the overspill is not acceptable, plan for a UniVox

®

 Super Loop System with 

®

®

minimized overspill. Log on to www.edin.se for more information.

●  Beware of the background noise created by other electrical equipment when planning the loop system.
●  Proceed to clause 2.

2. Installation

Mount the amplifi er

Mount the amplifi er vertically or horizontally. Use the drill mask to mark the positions for the holes. If the amplifi er is to be 

mounted in a 19"-rack, use a separate mounting panel (Part No 289011). The rubber feet should not bee removed. The

amplifi er must have free access to normal room temperature.

Connect the loop cable

Connect the loop cable to terminal F. on the rear panel. Please see page 4 for how to do 1- or 2-turn loop connections.

Connect signal source/s

Connect signal sources to the inputs  IN1-3, 

K., L. and M. on the rear panel. See page 4 for 

balanced/unbalanced connections. The inputs 

IN1 and IN2 can be set to different sensitivities 

according to table (right). If you need to set 

IN1 or IN2 otherwise than default, remove the 

cover and set the switches S1-6 according to 

the instruction at page 4.

Connect line outputs

UniVox

®

 PLS-100 has 2 line outputs; I. = LINE OUT 0dBm without the input AGC activated (linear), and J. SLS 0dBm with 

®

®

the AGC-function activated.

Connect mains power

Connect mains power to the inlet E. The LED D. on the front panel starts lighting. UniVox

®

 PLS-100 has an automatic 

resetable built-in mains fuse. If it’s triggered by any reason, please remove the mains power and let the amplifi er cool off. 

Investigate the possible fault reason before reconnecting the mains power.

3. Function check (basic start up check)

Adjust the input levels one by one letting the LED A. on the front panel light up distinctivly at the peaks of the program signal 

source (AGC knee).
Increase the Loop Current trimmer G. until the LED B. on the front panel lights up. Use the loop monitor output C. for direct 

listening to the output current (magnetic fi eld). If necessary, adjust TREBLE with the potentiometer H.

4. Certifi cation 

Very important!

Adjust the amplifi er following ”The UniVox Way” for certifi cation according to IEC-60118-4:2006 using a fi eld strength meter, 

like the UniVox

® 

FSM. If you don’t have access to the instrument, hire the service! Certifi cate and measuring guide are 

included with each amplifi er.

5. Information

Inform people responsible for the loop system how to use the system. Recommend a listening device for a daily basic check 

of the loop system. The UniVox

®

 Listener is a high quality listening device with built-in level check.

®

®

Page  3

Page 2

E. Mains 

connector

F. Loop wire 

connector

H. Treble

G. Loop 

current

J. SLS

L. IN 2

K. IN 3

M. IN 1

UniVox

®

 FSM 

®

®

Field Strength Meter 

UniVox

®

 Listener

®

®

Loop receiver/testing device

I. Line out

Loop area m²  Wire area, 1-turn-loop   Wire area, 2-turn-loop
75-170 

3.0mm² 

Not recommended

50-75 

1.5mm² 

2x1.5mm²

35-50 

1.0mm² 

2x1.0mm²

<35 

0.75mm² 

2x0.75mm²

Loop area m²  Wire area, 1-turn-loop   Wire area, 2-turn-loop
75-170 

3.0mm² 

Not recommended

50-75 

1.5mm² 

2x1.5mm²

35-50 

1.0mm² 

2x1.0mm²

<35 

0.75mm² 

2x0.75mm²

Loop area m²  Wire area, 1-turn-loop   Wire area, 2-turn-loop
75-170 

3.0mm² 

Not recommended

50-75 

1.5mm² 

2x1.5mm²

35-50 

1.0mm² 

2x1.0mm²

<35 

0.75mm² 

2x0.75mm²

Recommended minimum loop wire area for UniVox

®

 PLS-100, 

®

®

when installed to an existing loop system

Distributor

:

A. Input 

check

B. Loop 

check

D. Mains power check

C. Loop monitor, 

6.35mm jack and 

volume adjust.

 

Sensitivity 

Impedance

IN1 / Mic 

0.5mV-180mV 

10kOhm 

Default setting

IN1 / Line 

50mV-10V 

10kOhm

IN2 / Mic 

0.5mV-180mV 

10kOhm

IN2 / Line 

50mV-10V 

10kOhm 

Default setting

      IN3 

50mV-10V 

10kOhm

IN1 / Mic 

0.5mV-180mV 

10kOhm 

Default setting

IN1 / Line 

50mV-10V 

10kOhm

IN2 / Mic 

0.5mV-180mV 

10kOhm

IN2 / Line 

50mV-10V 

10kOhm 

Default setting

      IN3 

50mV-10V 

10kOhm

 

Sensitivity 

Impedance

IN1 / Mic 

0.5mV-180mV 

10kOhm 

Default setting

IN1 / Line 

50mV-10V 

10kOhm

IN2 / Mic 

0.5mV-180mV 

10kOhm

IN2 / Line 

50mV-10V 

10kOhm 

Default setting

      IN3 

50mV-10V 

10kOhm

 

Sensitivity 

Impedance

IN1 / Mic 

0.5mV-180mV 

10kOhm 

Default setting

IN2 / Line 

50mV-10V 

10kOhm 

Default setting

Reviews: