RECOMMENDED LOCATION OF ALARMS

• Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape

route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists,
locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters)
long, install a smoke alarm at each end.

• Locate additional smoke alarms to protect any stairway as stairways act like chimneys for

smoke and heat.

• Locate at least one smoke alarm on every floor level.
• Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are

operated in sleeping areas.

• Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting

the smoke alarm on the ceiling in the center of the room places it closest to all points in the room.
Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, wall
mounting on an inside partition is preferred to avoid the thermal barrier that may form at the
ceiling.

• When mounting smoke alarm on the ceiling, locate it a minimum of 4" (10cm) from a side wall

or corner (see Diagram A).

• When mounting smoke alarm on a wall, if local codes allow, use an inside wall with the top edge

of the smoke alarm a minimum of 4" (10cm) and a maximum of 12" (30.5cm) below the ceiling/
wall intersections (See Diagram A).

Sloped Ceilings (Peaked Ceilings):
Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (914 mm) horizontally
of the peak, but not closer than 4 in. (102 mm) vertically to the peak.

Sloped Ceilings (Shed Ceilings):
Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft. in 8 ft. (1 m in 8
m) horizontally shall be located within 36 in. (914 mm) of the high side of the ceiling, but not closer than 4 in. (102
mm) from the adjoining wall surface.

Tray-Shaped Ceilings:
Smoke Alarms or smoke detectors shall be installed on the highest portion of the ceiling or on the sloped portion
of the ceiling within 12 in. (305 mm) vertically down from the highest point.

Mobile Home Installation:
For minimum protection, smoke alarms  should be installed in compliance with H.U.D. Manufactured Home
Construction Safety Standards, Title 24 CFR, Section 3280.208 and Section 3282. For additional protection, see
Single Story Residence smoke alarm requirements/recommendations for Existing Homes and New Construction
Homes.

Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4” and 12” from the
ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if the ceiling
is unusually hot or cold.

Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area.

Existing Homes:
The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction. An
existing household with one level and one sleeping area is required to have one smoke alarm.

New Construction Homes and Manufactured Homes:
The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside each
bedroom area, and on every level of the home. They also require a minimum of two AC-powered, interconnected
smoke alarms in any new construction home.

Summary of Contents for SS-2895

Page 1: ... of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concerned about the limitations of battery or AC power install both types of units SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One unit should be i...

Page 2: ...102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the high...

Page 3: ...ve the smoke alarm s before high potting tests occur on the circuit or system Ref Section 550 17 National Electric Code 2002 Edition ELECTRICAL SHOCK HAZARD Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation Failure to turn off the power before installation may result in serious electrical shock injury or death TAMPER LOCKIN...

Page 4: ...anch circuit If local codes do not permit be sure the neutral wire is common to both phases The maximum wire run distance between the first and last alarm device in an interconnected system is 1 000 feet NOTE Use standard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores The wiring to be used shall be in accordance w...

Page 5: ...riters Laboratories Inc UL If you choose to use an aerosol smoke product to test the smoke alarm be certain to use one that has been Listed to Underwriters Laboratories Inc Safety Standards and use it only as directed Use of non UL Listed products or improper use of UL Listed products may affect the smoke alarm s sensitivity FALSE ALARMS SILENCE CONTROL Units with the silence feature have the capa...

Page 6: ... hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If inside door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there ...

Page 7: ... 5 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WA...

Reviews: