Page 21
DATA LOGIC SENSOR (OPTIONAL)
1. Remove one label from the liner to a get a bigger liner area.
2. Move the liner underneath the sensor cross hairs. Push and hold “Auto SET”
button until the green “READY” light turns off. Let go of the button.
3. The “READY” light will begin to flash.
4. Now move the
label
underneath the cross hairs. Push and hold ”AUTO SET”
button until green “Ready” light turns off. Let go of the button.
5. The “READY” light will now be
on
solid. The set procedure is now complete. If
you make a mistake or something went wrong, you can repeat the procedure.
6. If the sensor is set up correctly, the “OUT” light should come on in the label gap.
To make sure that it does, move the label around under the cross hairs to see if it
false detects called “hot spots” anywhere on the label.
7. If the sensor detects “hot spots” on the label, repeat steps 1-5 again. This time
when you put the label underneath the sensor put the specific “hot spot” under
the cross hairs.
8. Turning the power on or off does not affect sensitivity. Once the sensor is
programmed the values are burned into the chip inside the sensor.
Auto SET button
OUT Light
READY Light
Fig 19
Summary of Contents for L60
Page 1: ...L60 Label Applier Operator s Manual Serial ...
Page 33: ......
Page 35: ......
Page 37: ......
Page 39: ......
Page 41: ......
Page 43: ......
Page 45: ......
Page 47: ......
Page 49: ......
Page 51: ......
Page 53: ......
Page 55: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 62: ......
Page 64: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......