If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use
one that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it
only as directed. Use of non-UL Listed products or improper use of UL Listed products may
affect the smoke alarm's sensitivity.
NUISANCE ALARM SILENCE FEATURE:
This feature is to be used only when a known alarm
condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm Silence Feature
is activated by pushing and releasing the Silence button on the smoke alarm cover while in alarm
condition. The smoke alarm will automatically reduce sensitivity and the red LED will blink on approx.
every 10 seconds to indicate the alarm is in the Silence mode. The smoke alarm will gradually
regain normal sensitivity and sound the alarm if particles of combustion are still present. The 8-12
minute Silence feature may be used repeatedly until the air has cleared, by pushing and releasing
the Silence button again. Resetting the smoke alarm after a nuisance alarm is recommended.
NOTE: If the Test button is pressed and held during the Silence mode, the smoke alarm will be
tested normally. Upon the release of the Test button, the Silence mode will be restarted.
Before using the alarm Silence Feature, identify the source of smoke and be certain that
safe conditions exist.
Clean the smoke alarm at least once a month
to remove dust, dirt, insects or debris. Always
turn off power to smoke alarm before cleaning. Using a soft brush or wand attachment to a vacuum
cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris.
BATTERY REPLACEMENT
The smoke alarm uses a 9 Volt battery. The battery should last for at least one year under normal
operating conditions. The smoke alarm has a low battery indicator, an audible beep or chirp. It
will operate at approx. 40 second intervals for a minimum of 7 days. When this indication occurs,
replace the battery with an Alkaline type (Duracell MN1604, Energizer #522) or Lithium type (Ultralife
U9VL-J) from your local retailer.
LITHIUM Battery Models only
- The LITHIUM battery is warranted to last for 10 years under normal
operating conditions. Replace the battery with only LITHIUM type: (ULTRALIFE: U9VL-J).
OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN: To make your battery drawer tamper
resistant, a locking pin has been provided (breakaway part on mounting bracket).
NOTE: If this feature has been activated, you will need to deactivate it by removing the battery
drawer tamper pin located at side of battery drawer. Refer to Page 5.
Pull the QUICK DRAW
®
battery drawer open and remove the battery. While observing polarity, push
the replacement battery into the battery drawer until it is held securely in place. Carefully close the
battery drawer and reinstall the tamper pin.
Test the smoke alarm by pushing the TEST button on the smoke alarm cover until the alarm
sounds, then release.
IMPORTANT:
Under normal conditions, the test button should sound the alarm immediately after it
is pressed. There are special conditions that, when you press the Test button, you will experience
a delay of approx. 10-15 seconds before the alarm sounds. This delay occurs if the test button is
pressed during a self-diagnostic period. This occurs: (1) Upon initial power up; (2) After battery
replacement. Retest after 10-15 seconds.
REPAIRS AND SERVICES
This smoke alarms contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a
radioactive material.
The distribution of these ionization-type smoke alarms is licensed by
the U.S. Nuclear Regulatory Commission; the consumer is exempt from any licensing or
requirements.
If the smoke alarm is defective in any way, do not tamper with the smoke alarm.
Return the smoke alarm for servicing. (See warranty for instructions or in-warranty returns.) There
will be a service charge for repairing out of warranty smoke alarms.
NEVER use an open flame of any kind to test this smoke alarm. You might accidentally
damage or set fire to the smoke alarm or to your home. The built-in test switch accurately
tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).
The end-of-service life signal can be silenced for approximately 6 hours. To perform this function,
press and release the test button. The alarm will sound for approximately 60 seconds while it
resets. After the reset function is completed, the alarm will be silent for approximately 6 hours. The
end-of-service life signal will reactivate after the silence period.