c. Power on the scale and wait for the counting down
d. Scale is in zero weight status and display showing zero indicator
e. If zero indicator is not on, press
ZERO
to set the display to zero
f. If zero weight status cannot be obtained, change the location and try again
5.1 WEIGHING UNIT SELECTION
Press
MODE
to switch between metric and imperial.
5.2 TARE FUNCTION SETTING
This scale equips with auto tare, continuous tare (please refer to
F9
of internal
setting) and manual tare.
a. If auto tare function is enabled, the first weight being placed on platter will
be automatically tared
b. If continuous tare function is enabled, each weight being placed on platter
will be automatically tared
c. If manual tare is needed, place the load/container on the platter first and
press
TARE
to tare off the weight. After weight is tared,
NET
indicator will
appear indicating the weight showing on display is net weight
5.2.1 How To Clear Tare Function (auto tare, automatic continuous tare and
manual tare)
a. To clear auto tare, remove the initial weight/load from the platter and
NET
indicator will turn off. Press
ZERO
to return to zero weight status if
ZERO
indicator does not appear
b. To clear continuous tare, remove all loads from platter and
NET
indicator
will switch off. Press
ZERO
to return to zero weight status if
ZERO
indicator
does not appear
c. To clear manual tare, remove everything from platter and press
TARE
, the
NET
indicator will turn off. Press
ZERO
to return to zero weight status if
ZERO
indicator does not appear
5.3 MEMORY FUNCTION
5.3.1 How To Save A Weighing Result To Memory
a. Place a load on the scale and result will show on the display
b. Wait the Stable signal appears then press
M+/MC
c. Weight result is now saved to memory and
M+
indicator appears indicating
memory contains data
d. Remove the load and scale will return to zero weight status
e. Put on another weight and press
M+/MC
to save the next weight