FLORIDA-PNEUMATIC.COM
Please contact 1-800-356-3392 for further assistance.
□
Remove the flange
nut with the disc
spanner.
□
Mount the grinding
wheel on the spindle.
□
Replace the flange nut
and re-tighten using
the disc spanner.
□
Remove flange nut with the disc spanner.
□
Remove the grinding wheel, and replace the flange nut
using the disc spanner.
Operation
1
Operating the angle grinder
□
This Angle Grinder is designed to operate on 90 PSIG.
Lower pressure (below 90 PSIG) will reduce performance
of the tool. Higher air pressure (over 90 PSIG) raises the
performance of the tool beyond its rated capacity and
could cause serious damage to the tool and the user.
2
Installing the grinding wheel
WARNING:
Disconnect the tool from the air supply before
servicing or changing accessories.
WARNING:
Always use ANSI approved grinding wheel with
the rated tool RPM.
3
Removing the grinding wheel
WARNING:
Disconnect the tool from the air supply before
servicing or changing accessories.
4
Grinding and deburring
WARNING:
You must wear the ANSI approved eye
protection during the operation; failure to follow this this may
result in serious injury or damage to the operator.
WARNING:
Hearing protection is strongly recommended. A
protective respirator is recommended.
□
Connect the grinder to the air supply.
□
This tool features the safety lock-off mechanism.
□
Operate the tool by disengaging the lock-off mechanism
and depressing the throttle lever to run the tool for grinding
or deburring.