Warranty

Limited Warranty: Universal Tool warrants its tools to be free from defects in material and workmanship for one year from the date of 

Tool or its authorized service centers. If a UT tool proves defective in material or workmanship within one year after purchase, return 
it to any authorized service center or Universal Tool freight prepaid. Please enclose your name, address and adequate proof of date of 
purchase and a short description of the defect. Universal Tool will,at its option, repair or replace defective tools free of charge. Repairs or 
replacements are warranted as described above for the remainder of the original warranty period. Universal Tool's sole liability  and your 
exclusive remedy under this warranty is limited to repair or replacement of 

Troubleshooting

Problem

Possible Cause

Solution

The tool runs slowly or will not 
operate.

There is grit or gum in the tool.

Flush the tool with air tool oil or gum solvent.

The tool is out of oil.

Lubricate the tool according to the lubrication 
instructions in this manual.

The air pressure is low.

  Adjust the regulator on the tool to the 

maximum setting.

  Adjust the compressor regulator to the tool’s 

maximum setting of 90 psi.

The air hose leaks.

tape if leaks are found.

The air pressure drops.

  Ensure the hose is the proper size. Long 

hoses or tools using large volumes of air may 
require a hose with an I.D. of ½" or larger 
depending on the total length of the hose.

  Do not use a multiple number of hoses 

connected together with a quick connect 

and reduces the tool power. Directly connect 
the hoses together.

There is a worn rotor blade in the motor. 

Replace the rotor blade.

There is a worn ball bearing in the motor.

Remove and inspect the bearing for rust, dirt, and 
grit. Replace or clean and grease the bearing with 
bearing grease.

There is moisture blowing out 
of the tool’s exhaust.

There is water in the tank.

Drain the tank. (See the air compressor manual 
for instructions.) Lubricate the tool and run it until 
water is not evident. Lubricate the tool again and 
run for 1-2 seconds.

The tool impacts slowly or not 
at all.

The tool needs lubricating.

Lubricate the air motor and the impact mechanism  
according to the lubrication instructions in this 
manual.

The tool regulator setting is in the wrong position.

Adjust the regulator on the tool to the maximum 
setting.

The tool impacts rapidly, but 
will not remove bolts.

The tool has a worn impact mechanism.

Replace the worn impact mechanism components.

The tool does not impact.

The impact mechanism is broken.

Replace the broken impact mechanism 
components.

Summary of Contents for UT8027R

Page 1: ...shooting 6 Warranty 6 Service Parts 7 Universal Tool a Division of Florida Pneumatic Mfg Corp 851 Jupiter Park Lane Jupiter FL 33458 Universal Air Tools Company Ltd Unit 8 Lane End Industrial Park Hig...

Page 2: ...2 2 3 GENERAL SAFETY RULES 7 2 2 4 PROJECTILE HAZARDS 7 2 2 5 ENTANGLEMENT HAZARDS 7 2 2 6 OPERATING HAZARDS 7 2 2 7 REPETITIVE MOTIONS HAZARDS 7 2 2 8 ACCESSORY HAZARDS 7 2 2 9 WORKPLACE HAZARDS 7 2...

Page 3: ...e of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as dust masks that Important Warnings Impacts 1 Eye protection and hear...

Page 4: ...line Regulator F In line Lubricator G In line Filter H Air Compressor Ensure the air line is shut off and drained of air before removing this tool for service or changing sockets This will prevent th...

Page 5: ...tures a power management switch A Turn the regulator until the desired output torque level is achieved Turning the regulator to the left increases speed and torque while turning it to the right reduce...

Page 6: ...on the tool to the maximum setting Adjust the compressor regulator to the tool s maximum setting of 90 psi The air hose leaks tape if leaks are found The air pressure drops Ensure the hose is the prop...

Page 7: ...er Cage 1 28 9106283 Air Regulator 1 7 9106263 Hammer Dog 1 29 9106284 O Ring 1 8 9106264 Hammer Pin 2 30 9106285 Valve Sleeve 1 9 9106265 Washer 1 31 9106286 Dowel Pin 1 10 9106266 Ball Bearing 1 32...

Page 8: ...883300 Universal Air Tools Company Ltd Unit 8 Lane End Industrial Park High Wycombe HP14 3BY UK sales universal co uk www universal co uk Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356...