Operation

Operating the die grinder

 

This Die Grinder is designed to operate on 90 PSIG. Lower 
pressure (below 90 PSIG) will reduce performance of 
the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 
 
 
 
 
 

Installing the grinding stone 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

Removing the grinding stone 

 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

 

Loosen the collet nut with the 17 MM wrench (B) and the 11 
MM wrench (C) on the tool (A). 

 

Pull the grinding stone out and tighten the collec nut with the 
17 MM wrench (B) and the 11 MM wrench (C) on the tool (A).

Grinding and deburring 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

protective respirator is recommended.

 

Loosen the collet nut with the 17 MM wrench (B) and the 11 
MM wrench (C) on the tool (A).

 

Insert the grinding stone in the collet. If using a 1/8 in. collet 
stone, an adapter (not included) must be inserted before 
placing the stone into the tool.

 

Tighten the collet nut with the 17 MM wrench (B) and the 11 
MM wrench (C) on the tool (A).

 

Connect the die grinder to the air supply.  

 

This tool features the safety lock-off mechanism.

 

Operate the tool by disengaging the lock-off mechanism and 
depressing the throttle lever to run the tool for grinding or 
deburring. 

Summary of Contents for UT4425-1

Page 1: ...ng any pneumatic tool TABLE OF CONTENTS General Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6...

Page 2: ...used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis r...

Page 3: ...filter out microscopic particles Important Warnings Die Grinders Specifications 1 Only use mounted grinding stones or mounted carbide burrs that meet ANSI standards ISO standards or both 2 Never adjus...

Page 4: ...ttle is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regularly check and fill the in line...

Page 5: ...wrench C on the tool A Pull the grinding stone out and tighten the collec nut with the 17 MM wrench B and the 11 MM wrench C on the tool A 4 Grinding and deburring WARNING You must wear the ANSI appro...

Page 6: ...rease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evid...

Page 7: ...FLORIDA PNEUMATIC COM Please contact 1 800 356 3392 for further assistance Service Parts Exploded View Drawing UT4425 1 Die Grinder UT4425E 1 Extended Die Grinder...