Universal Tool UT2740-1 Safety Information Manual Download Page 5

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Operation

Operating the angle grinder

 

This Angle Grinder is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 
  
 
 
 

Installing the grinding wheel 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

Removing the grinding wheel 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

Grinding 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

protective respirator is recommended.

 

 

Connect the grinder to the air supply.  

 

This tool features the safety lock-off mechanism.

 

Operate the tool by disengaging the lock-off mechanism 
and depressing the throttle lever to run the tool for grinding.

 

Remove flange nut with the spanner and pin wrench.

 

Remove the grinding wheel, and replace the flange nut 
using the spanner and pin wrench.

Lever

 

Remove the flange nut with the 
spanner and pin wrench.

 

Mount the grinding wheel on the 
spindle. 

 

Replace the flange nut and re-
tighten using the spanner and pin 
wrench.

Summary of Contents for UT2740-1

Page 1: ...ENTS General Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 UT2740...

Page 2: ...used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis r...

Page 3: ...ff wheels shall not be used for side grinding Exception grinding wheels designed for side grinding Grinders should not be used over the maximum rated speed of an abrasive product 5 The operator shall...

Page 4: ...ly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding t...

Page 5: ...l from the air supply before servicing or changing accessories 4 Grinding WARNING You must wear the ANSI approved eye protection during the operation failure to follow this this may result in serious...

Page 6: ...rease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evid...