RESET INSTRUCTIONS: Press the Test/Silence button for 10-15 seconds and then release. This will clear the alarm origination. Be sure to RESET 

alarms after each alarm event. QUICK FIND

®

 Alarm Origination/Location Feature: The QUICK FIND

®

 feature will allow you to immediately locate the 

originating alarm (the alarm that triggered the other alarms), once the alarms have stopped sounding.  

1. Press and release the Test/Silence button on alarm. After releasing the button, the test sequence on this alarm will begin, and 

    last approximately 5-20 seconds.  If it is not the originating alarm, continue to each alarm until the originating alarm is located.

2. Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to  

     locate the originating alarm.  

3. Remember to reset the originating alarm in order to clear the QUICK FIND

®

 and return the system to normal operation.  

NOTE: If you have any additional questions about the operation of this product, please contact our Customer Service Department  

at 800-390-4321, and we will gladly assist you. 

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 8TH EDITION and UL 2034 4th Edition.

Quick Reference Guide Model AMIC3511S (continued from previous page)

Summary of Contents for Sensing Plus AMIC3511S

Page 1: ...uct Features 2 Alarm Limitations and Functions 2 Installation Instructions 3 Where This Alarm Should Be Installed 3 Where This Alarm Should Not Be Installed 5 Mounting Instructions 6 Tamper Resistant...

Page 2: ...UNCTIONS IMPORTANT ALARMS WILL NOT WORK WITHOUT POWER Therefore installing an alarm with a sealed battery or an alarm powered from two different power sources can give an extra measure of protection A...

Page 3: ...ays be replaced after 10 years DO NOT PAINT THE ALARM Paint may clog the openings to the sensing chambers and prevent the alarm from operating properly DO NOT STAND TOO CLOSE TO THE ALARM WHEN IT IS S...

Page 4: ...wall with the top edge of the smoke alarm up to a maximum of 12 30 5cm below the ceiling wall intersec tions See Diagram A Existing Homes The NFPA requires smoke alarms or combination alarms on every...

Page 5: ...ional Electrical Code To avoid causing damage to this alarm to provide maximum protection and to prevent unnecessary alarms DO NOT LOCATE THIS ALARM In extremely humid areas This alarm should be at le...

Page 6: ...anted nuisance alarms Nuisance alarms may occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible MOUNTING INSTRUCTIONS To use the optional Alarm T...

Page 7: ...asements and excluding crawl spaces and unfinished attics 5 In the living area s of a guest suite 6 In the living area s of a residential board and care occupancy small facility The equipment should b...

Page 8: ...e the Silence feature until the source of the alarm has been identified and safe conditions exist The Silence feature is intended to temporarily silence the horn while identifying and correcting the p...

Page 9: ...ill a problem call customer service Do not attempt to fix the alarm ALARM AND BATTERY DEACTIVATION This alarm uses a sealed battery for power The battery should last for approximately 10 years under n...

Page 10: ...rm to stop a nuisance alarm Doing so will disable the alarm and remove the protection In the case of a true unwanted alarm use the silence feature The silence feature is intended to temporarily silenc...

Page 11: ...Vent pipe connections improperly designed or becoming loose Improper use of appliances by operating a barbeque grill using charcoal gas or wood pellets hibachi in an enclosed area such as a garage or...

Page 12: ...our home when they hear the sound Identify children s bedrooms with red stickers placed in the upper left corner of the windows They are available from your local fire department Practice a fire drill...

Page 13: ...t Silence button for 10 15 seconds This will clear alarm origina tion Reset after each alarm event Previous alarm condition at unidentified source Silent alarmed previously Blinks on approx every 2 mi...

Page 14: ...imately 5 20 seconds If it is not the originating alarm continue to each alarm until the originating alarm is located 2 Once this test sequence ends the originating alarm continues to sound for approx...

Page 15: ...n or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you No agent representative dealer or employee of the company has the authority to increa...

Reviews: