Universal Security Instruments Sensing Plus AMI3051S Instructions Manual Download Page 9

Silent

Test/Silence

 Button Has

 Been Pressed

Blinks On in sync

with Horn

Nuisance

Alarm

3 Beeps,

2 second pause,

Repeat

If  there  is  no  hazard  present,  verify  the  alarm  is  mounted 
in  the  correct  location  (see  User's  Manual,  "AVOID  THESE 
LOCATIONS" section). Reset alarm as instructed below.

Alarm needs to

be reset due 

to varying 

conditions/

previous alarms

Off

HORN

ALARM AUDIBLE & VISUAL SIGNALS

New - Out

of Package

CONDITION

Quick Reference Guide Model AMI3051S

Low Battery

1 chirp

approx every

60 seconds

Deactivate alarm (see User's Manual "ALARM DEACTIVATION" 
section). Replace alarm immediately.

Blinks On once

approx every

2 minutes

RECOMMENDATION

DC Power is 

Present

Silent

Blinks On once 

approx every

2 minutes

Silent

To activate the alarm, remove the pull tab. The alarm will sound 
one long beep to confirm it is powered up. Press the Test/Silence 
button. Test the alarm following installation and weekly thereafter. 
The  built-in  test  switch  accurately  tests  the  alarm  operation  as 
required  by ANSI/UL217  Standards  for  Safety.  If,  at  any  time, 
you test the alarm and it does not perform as described, replace 
it immediately.

The alarm is operating properly.

RED LED

3 beeps,

2 second pause,

The alarm is operating properly.

Blinks On in sync

with Horn

Alarm Reset

 - Press and Hold the Test/Silence button for approximately 10 seconds and release. This will clear the Silence 

Feature and Alarm Origination.

THIS PRODUCT CONFORMS TO UL STANDARD 217 8TH EDITION FOR SAFETY

3 Beeps,

2 second pause,

Repeat

Blinks On in sync

with Horn

If hazard is identified, please take all precautions if an alarm 
sounds by calling an Emergency Service and getting out of 
the home.

3 Beeps,

2 second pause,

Repeat

Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition. 
Silence mode will last for approx 10 minutes with the red LED 
blinking once approx. every 10 seconds.

Blinks On in sync

with Horn

Alarm has 

Sensed Smoke

Blinks On once

approx every

2 minutes

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Silent

(alarmed

previously)

QUICK FIND

®

 Alarm Origination - The QUICK FIND

®

 feature will 

allow you to locate the originating alarm (once the alarms have 
stopped sounding). To initiate QUICK FIND

®

, press the Test/

Silence button. After releasing the button, the originating alarm 
will continue to sound for approx 60 seconds. It is necessary to 
test each alarm to determine the originating alarm.

Alarm has 

Previously

Sensed Smoke

To reset the alarm, hold the Test/Silence button for approx 10 
seconds and release. This will clear Alarm Origination. Reset 
alarm after every alarm event.

Blinks On once

approx every

2 minutes

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Originating

Smoke Alarm

Product

End-of-Service

Life Notification

2 chirps

approx every

60 seconds

Blinks On once

approx every

2 minutes

Deactivate alarm (see "ALARM DEACTIVATION" section in 
User's Manual). Replace alarm immediately.

Page 9

(Alarm 

Calibration) 

Warning

Silent

3 Blinks approx. 
every 2 minutes

Clean Alarm. See MAINTENANCE instructions on the following 
page. Reset the alarm. See Reset Instructions below. If this 
does not clear the problem, replace alarm. Deactivate Alarm. 
See User's Manual "ALARM DEACTIVATION" section. Replace 
alarm immediately.

Summary of Contents for Sensing Plus AMI3051S

Page 1: ...which could help protect you and your family This alarm detects products of combustion using a multi criteria sensor TABLE OF CONTENTS PAGE Smoke Alarm Limitations and Functions 2 Recommended Locatio...

Page 2: ...LARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke fro...

Page 3: ...er than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings S...

Page 4: ...r operation This alarm will not work until it is activated and properly installed This alarm should be tested immediately after installation and then tested weekly after that If the alarm ever fails t...

Page 5: ...itions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self dia...

Page 6: ...or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or gre...

Page 7: ...4 turn 6 This will discharge the alarm battery and stop the alarm chirping after approximately one minute The alarm is now ready for disposal 7 The deactivation key should not be removed and the alarm...

Page 8: ...m Code NFPA 72 reads as follows 29 8 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall...

Page 9: ...precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button...

Page 10: ...r replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant...

Reviews: