background image

TO DEACTIVATE THE LOCKING FEATURES:

 To remove the smoke alarm for cleaning or servicing

or to replace the battery, you must first remove the appropriate locking pin, if it has been installed.

1.

Use long nose pliers to pull the locking pin out of the hole.

2.

It is now possible to remove the smoke alarm or replace the battery.

Page 5

MOUNTING INSTRUCTIONS

1.

Attach the mounting bracket in the proper location on the wall or ceiling (screws and anchors
provided).

2.

To activate 9 volt battery and alarm, hold the battery, pull and remove the PULL-TAB.  Confirm
that the entire PULL-TAB has been completely removed. Discard PULL-TAB.

3.

Push and twist the alarm clockwise onto the mounting bracket.

4.

See "OPTIONAL TAMPER RESISTANT FEATURE" and "TO ACTIVATE THE LOCKING
FEATURE" instructions on Page 4.

5.

The red LED will blink on approx. every 40-45 seconds to indicate proper operation.

OPERATION, TESTING & MAINTENANCE

OPERATION:

 The smoke alarm is operating once the battery power is connected by removing the

PULL-TAB. When products of combustion are sensed, the alarm sounds a loud alarm which continues
until the air is cleared.
This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the
horn produces three beeps followed by a two second pause and then continually repeats.

READY/ACTIVE CONDITION:

 The red LED blinks on once approx. every 40-45 seconds to indicate

the alarm is properly functioning.

ALARM CONDITION:

 The red LED blinks on once approx. every 2 seconds and the alarm emits a

loud, pulsating alarm sound.

NUISANCE ALARMS:

 

The smoke alarm is designed to minimize nuisance alarms. Smoking will

not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion
particles from cooking may set off the alarm if the smoke alarm is located close  to the kitchen
cooking surface. Large quantities of combustion particles are generated from spills or broiling.
If the smoke alarm does sound, check for fires first. If a fire is discovered, get out and call the fire
department. If no fire is present, check to see if one of the reasons listed above may have caused
the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and
holding the test button for ten seconds. Refer to RESET below.

TESTING:

 Test by pushing the Test button on the smoke alarm cover until the alarm sounds, then

release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm sounds,
the alarm may have a power supply failure. 

Test the smoke alarm weekly to assure proper

operation.

ALARM ORIGINATION: 

The QUICK FIND

®

 feature will allow you to immediately locate the originating

alarm (once the alarm has stopped sounding). To initiate QUICK FIND

®

, press the Test/Silence

button on each alarm. After releasing the button, the originating alarm will continue to sound for 60
seconds. In a non-interconnected installation, it is necessary to test each alarm to determine the
originating alarm.

RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the Test button

on any alarm for at least 10 seconds and then release. Reset after each alarm. The reset
feature will reset all interconnected units.
END-OF-SERVICE LIFE NOTIFICATION:

 A majority of home fire deaths are a result of no smoke

alarms or no 

working

 smoke alarms. In addition to the "replace by date" stamped on the back of your

alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time
to replace your alarm, which is after approximately 10 years of operation from initial power up, the
alarm will sound 1 beep approx. every 60 seconds and the red LED will blink on once approx. every
40-45 seconds. The alarm should be replaced immediately.
The end-of-service life signal can be silenced for approximately 6 hours. To perform this function,
press and release the test button. The alarm will sound for approximately 60 seconds while it resets.
After the reset function is completed, the alarm will be silent for approximately 6 hours. The end-of-
service life signal will activate after the silence period.

Summary of Contents for MI3050

Page 1: ...5 Operation Testing Maintenance 6 QUICK FIND Alarm Originating Feature Reset 5 Cautions Warnings 5 Battery Replacement 6 Develop and Practice a Plan of Escape 8 Operational Summary 9 Warranty Back Co...

Page 2: ...VERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INS...

Page 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Page 4: ...arms with photoelectric sensors or smoke alarms with Silence Feature for these areas in areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3 feet 0...

Page 5: ...ck for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed above may have caused the alarm Use the Silence Feature...

Page 6: ...522 Duracell MN1604 or Lithium type Ultralife U9VL J from your local retailer LITHIUM Battery Models only The LITHUM battery is warranted to last for 10 years under normal operating conditions Replace...

Page 7: ...gainst it open it slightly and be ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your...

Page 8: ...ormal operation mode or Blinks on once approx every 10 seconds silence mode Originating smoke alarm If hazard is identified please take all precautions if an alarm sounds by calling an Emergency Servi...

Page 9: ...ions E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty an...

Reviews: