AVOID THESE LOCATIONS

• the garage – products of combustion are produced when you start your vehicle.
• near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces,

gas hot water heaters). Use smoke alarms with photoelectric sensors or smoke alarms with
Silence Feature  for these areas.

• in areas with high humidity, like bathrooms or areas near dishwashers or washing machines.

Install at least 3 feet (0.9 meters) away from these areas.

• in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms

shall not be located where airflow prevents smoke from reaching the alarms.

• in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm operation.
• in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

• closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the

alarm's operation.

• closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan.
• on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

Page 4

Early warning fire detection is best achieved by the installation of fire detection equipment in
all rooms and areas of the household as follows: A smoke alarm installed in each separate
sleeping area (in the vicinity of, but outside of, the bedrooms); and, as appropriate, heat or
smoke alarms in living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets,
utility storage rooms, basements and attached garages. Test the alarms weekly to assure
proper operation.

CAUTION: THIS SMOKE ALARM IS SEALED. THE COVER IS NOT REMOVABLE

!

• A mounting bracket is provided on the back of the alarm.

• Remove the mounting bracket from the back of the alarm by holding the mounting bracket and

twisting the alarm in the direction indicated by the "TWIST TO REMOVE" arrow on the side of the
alarm base.

OPTIONAL TAMPER RESISTANT FEATURES:

 There are two separate tamper resistant locking

features provided for this model. Activating one or both of these features deters someone from
removing the smoke alarm from the mounting bracket or removing the battery from the alarm. The
breakaway locking pins are clearly marked and molded into the mounting bracket. Refer to the
diagram on the next page.

TO ACTIVATE THE LOCKING FEATURES:

 Do not activate the locking features until you have

activated the battery, mounted the smoke alarm to the bracket and tested the smoke alarm. Refer to
OPERATION, TESTING & MAINTENANCE instructions on Page 5.

1.

Detach the breakaway alarm locking pin from the mounting bracket.

2.

Insert the pin into the hole for the feature you are activating. Refer to the diagram below for
correct placement.

ALARM/BRACKET

LOCKING PIN

BATTERY LOCKING PIN

INSERT ALARM

LOCKING PIN HERE

INSERT BATTERY

LOCKING PIN HERE

THIS SMOKE ALARM WILL NOT WORK WITHOUT A GOOD BATTERY
PROPERLY INSTALLED. THE SMOKE ALARM SHOULD BE TESTED WHEN
INSTALLED AND THEN TESTED WEEKLY AFTER THAT.

TO DEACTIVATE THE LOCKING FEATURES:

 To remove the smoke alarm for cleaning or servicing

or to replace the battery, you must first remove the appropriate locking pin, if it has been installed.
1.

Use long nose pliers to pull the locking pin out of the hole.

2.

It is now possible to remove the smoke alarm or replace the battery.

Summary of Contents for MDS300

Page 1: ...tions 5 Operation Testing Maintenance 5 RV Installation 5 QUICK FIND Alarm Originating Feature Reset 5 Silence Feature 6 Cautions Warnings 6 Battery Replacement 6 Develop and Practice a Plan of Escape...

Page 2: ...PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES BUT SMOKE ALARMS ARE NOT A...

Page 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Page 4: ...ms weekly to assure proper operation CAUTION THIS SMOKE ALARM IS SEALED THE COVER IS NOT REMOVABLE A mounting bracket is provided on the back of the alarm Remove the mounting bracket from the back of...

Page 5: ...n on the smoke alarm cover until the alarm sounds then release The alarm sounds if all electronic circuitry horn and battery are working If no alarm sounds the alarm may have a power supply failure Te...

Page 6: ...under normal operating conditions Replace the battery with only LITHIUM type ULTRALIFE U9VL J OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN To make your battery drawer tamper resistant a locking pin has...

Page 7: ...eryone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so NATIONAL FIRE PROTECTION ASSOCIAT...

Page 8: ...stallation Blinks On once approx every 40 45 seconds Condition Alarm needs to be reset due to varying conditions previous alarms Recommendation To Reset theAlarm hold the Test Silence button for appro...

Page 9: ...NT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE...

Reviews: