Unitronics 

 

 

Vision™ OPLC™ 

V350-35-TR20 
Installation Guide  

The Unitronics V350-35-TR20 offers the following onboard I/Os: 

  12 Digital Inputs, configurable via wiring to include 2 Analog, and 3 HSC/Shaft-encoder Inputs   

  6 Relay Outputs 

  2 high-speed npn Transistor Outputs 

General Description 

V350 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise:  

  On-board I/O configuration 

  Built-

in operating panel containing a 3.5” Color Touchscreen and programmable function keys 

Communications 

  1 built-in serial port: RS232/RS485 

  Optional: the user may order and 

install one or both of the following 
modules:  
- RS232/RS485/Ethernet  
- CANbus 

  Communication Function Blocks 

include: SMS, GPRS, MODBUS 
serial/IP. Protocol FB enables PLC to 
communicate with almost any external 
device, via serial or Ethernet 
communications  

 

I/O Options 

V350 supports digital, high-speed, analog, 
weight and temperature measurement I/Os via: 

  On-board I/O configuration  

Model-dependent 

  I/O Expansion Modules 

Local or remote I/Os may be added via 
expansion port or CANbus. 

 

Information Mode 

This mode enables you to: 

  View & Edit operand values, COM port settings, RTC and screen 

contrast/brightness settings 

  Stop, initialize, and reset the PLC 

To enter Information Mode, press the <i> button for several seconds. 

Programming 
Software,  
& Utilities 

The Unitronics Setup CD contains VisiLogic software and other utilities. 

  VisiLogic  

Easily configure hardware and write both HMI and Ladder control 
applications; the Function Block library simplifies complex tasks such 
as PID. Write your application, and then download it to the controller 
via the programming cable included in the kit. 

  Utilities 

Includes UniOPC server, Remote Access for remote programming 
and diagnostics, and DataXport for run-time data logging. 

To learn how to use and program the controller, as well as use utilities such 
as Remote Access, refer to the VisiLogic Help system. 

 

Summary of Contents for Vision OPLC V350-35-TR20

Page 1: ...ital high speed analog weight and temperature measurement I Os via On board I O configuration Model dependent I O Expansion Modules Local or remote I Os may be added via expansion port or CANbus Information Mode This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Stop initialize and reset the PLC To enter Information Mode press the i butt...

Page 2: ...t the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs ...

Page 3: ...ller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure ...

Page 4: ...on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ens...

Page 5: ...eset as part of a shaft encoder or as normal digital inputs If inputs 0 2 4 are set as high speed counters without reset inputs 1 3 5 can function as normal digital inputs Input Jumper Settings The tables below show how to set a specific jumper to change input functionality To access the I O jumpers you must open the controller according to the instructions beginning on page 9 Incompatible jumper ...

Page 6: ...0 35 TR20 Installation Guide 6 Unitronics I O Wiring I O Configuration npn Input Wiring Input wiring npn sink HSC input wiring npn sink pnp Input Wiring Input wiring pnp source HSC input wiring pnp source ...

Page 7: ...signal s source The 0V signal of the analog input must be connected to the controller s 0V Relay Outputs Increasing Contact Life Span To increase the life span of the relay output contacts and protect the device from potential damage by reverse EMF connect A clamping diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC load ...

Page 8: ...o maximize system performance avoid electromagnetic interference by Mounting the controller on a metal panel Connect each common and ground connection directly to the earth ground of your system For ground wiring use the shortest and thickest possible wire Communication Port Turn off power before making communications connections Caution Signals are related to the controller s 0V the same 0V is us...

Page 9: ... 1 DTR is used for signal A and Pin 6 DSR signal is used for signal B RS232 to RS485 Jumper Settings The figure to the right shows the jumper factory default settings RS232 RS485 termination ON Note that in order To change the communication setting to RS485 both communication standard jumpers must be moved To change the RS485 termination both termination jumpers must be moved To access the jumpers...

Page 10: ...the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but ...

Reviews: