UniTraQ International Corp.
RoHS compliance
.
2012,07, Version 1.3
15
Mini Tracker Model: MT-900C
(2) Using PC Hyper Terminal tool
(a) Power on the device. Using USB cable connects the device with PC.
Check if the device access to the PC’s COM port.
My Computer>Properties>Hardware>Device >Manager>Ports (COM&LPT)
(b) Open the Hyper Terminal, and select the corresponding COM.
The baud rate is 115200, 8 data bits, none parity check, 1 stop bit, none flow control.
(c) Input “updmtfm” and Enter in HyperTerminal.
(d)
Select the file which to be downloaded via “Transfer” -> “Send File” of the
HyperTerminal as the figure.
(e) After all, press the “Send” button to download file from PC.And then you will see the
download progress.