![Unitor AD-PRO 1800 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/unitor/ad-pro-1800/ad-pro-1800_instruction-manual_845368007.webp)
Disconnect the hammer from the air supply before lubricating.
1. Disconnect the drill from the air supply.
2. Remove the slotted screw Allen head screw from the oil porthole on the right side of the tool that
has "
OIL
" stamped below the hole for.
3. Put three teaspoons of air tool oil in the oil porthole. Replace the screw.
4. Reconnect the air supply to the hammer and run for 20 to 30 seconds.
Lubricate the entire scaling mechanism by rotating the tool upside down and sideways while
running the tool.
5. Remove the screw and hold the oil port hole over a suitable container to allow excess oil to
drain.
6. If the oil is dirty, repeat the procedure above until the oil comes out clear. Install the screw and
tighten. The residual oil remaining in the scaling mechanism chamber is all that is needed for
proper lubrication.
6.