MACHINE INSTALLATION
3.01. T h e Unibond I I i s shipped i n a s i n g l e container which c o n t a i n s t h e C o n t r o l
and t h e Output Transformer. T h e Meter Accessory i s shipped i n a separate c a r t o n .
3.02. C O N N E C T UNIBOND FOR PROPER LINE VOLTAGE - The Unibond i s a m u l t i v o l t a g e p o -
wer s u p p l y. R e f e r t o t h e Connection Diagrams shown i n Figure 3 6 . I t can b e connected
for 1 0 0 . 11 5 . 2 0 8 o r 230 v o l t s . 5 0 o r 6 0 H z . b y changing ( a ) t h e C i r c u i t Breaker ( b )
the Plug on t h e end o f t h e L i n e Cord and ( c ) t h e p o s i t i o n o f t h e jumpers o n t h e Con-
t r o l Transformer ( F i g u r e 3 3 ) a s i n d i c a t e d below:
TABLE I - Unibond I I C o n t r o l Transformer Connections
CIRCUIT
T
E
R
M
I
N
A
L
N U M B E R
VOLTAGE B R E A K E R
1
2
3
4
5
6
100 VOLTS 2 Amp L I N E 1 T E R M 5 N / C T E R M 1 L I N E 2 N / C
115 VOLTS 2 Amp L I N E 1 N / C T E R M 6 T E R M 1 N / C L I N E 2
208 VOLTS 1 Amp L I N E 1 T E R M 4 N / C T E R M 2 L I N E 2 N / C
220 VOLTS 1 Amp L I N E 1 N / C T E R M 4 T E R M 3 L I N E 2 N / C
230 VOLTS 1 Amp L I N E 1 N / C T E R M 4 T E R M 3 N / C L I N E 2
N/C = No Connection
P i l o t L i g h t i s always connected between Terminals 4 and 6 .
- 1 0 -