Safety advices
Machinery directive
The manufacturer of the machine or installation must draw up a hazard analysis for his product. He
must make sure that any unpredictable movements do not cause damage neither to persons nor to
property.
Skilled personnel
Hardware
The skilled qualified personnel must feature a training and instruction for an assignment in the field of
electronic drive engineering. They must have knowledge of the standards and accident prevention
regulations for drive engineering applications and they must be familiar with this field of activity.
Eventually occurring dangerous situations are realized.
The local regulations (IEC, VDE, VGB) are known to the qualified personnel and they are observed during
the works.
Software
The skilled qualified personnel for handling the software must be trained to safely program the units in
the machines and installations. Incorrect parameter settings may cause improper and impermissible
movements. Any parameter settings have to be checked for faulty operation. Acceptance tests must be
thoroughly carried out according the four-eyes principle
Working environment
Incorrect handling of the units may cause damage to persons or property.
The units must be closed during operation.
Any unit covers must not be removed.
Disconnect the power supply prior to any works on electric connections. It must be ensured the battery
voltage is safely switched off.
Any voltages and residual voltages (buffer circuit) must be measured prior to any works on the unit.
Max. permissible voltage < 42 V.
High temperatures > 70 °C may arise.
The working environment may be dangerous for persons having electronic medical aids or appliances
(e.g. cardiac pacemakers). Sufficient distance to these electrical parts must be observed.
Exposure
During transport and storage the prescribed and specified climatic conditions must be adhered to.
The units must not be mechanically damaged. Warped and bent housing parts may influence or damage
the isolation distances. Damaged units must never be installed!
The units comprise parts which may be damaged by electrostatic discharge. The general
recommendations for handling electrostatic devices must be observed. Special attention should be paid
to strongly isolating plastic films and synthetic fiber.
For the operation it must be ensured that the environmental conditions in the switch cabinet are
adhered to. This applies in particular to the impermissible condensation on the units.