Basic - Information
Version: 2021 / V2
Page: 11
BAMOCAR-PG-D3-700/250, 400
1.10
Details of the safety instructions
Machinery Directive
The vehicle, machine or plant manufacturer must prepare a hazard analysis for his product. He must
ensure that no unforeseeable movements can lead to personal injury or damage to property.
Qualified staff
Hardware
Qualified personnel are characterised by education and training for the use of electronic drive
technology. They know the standards and accident prevention regulations for drive technology and can
assess the application. Possible dangers are recognised.
The local regulations (IEC, VDE, VGB) are known to the qualified personnel and are taken into account.
Software
Qualified personnel for the software must be trained for the safe programming of the devices in the
machines and systems. Incorrect parameterisation can lead to unauthorised movements. The parameter
settings must be checked against incorrect operation. Careful acceptance tests are to be carried out
with a 4-eyes principle
Working environment
Incorrect handling of the units can lead to damage to property or personal injury.
Only operate the units when the unit is closed or the control cabinet is secured!
Unit covers must not be removed.
Work on electrical connections only in a de-energised state.
The battery voltage must be safely switched off.
The voltages and residual voltages (intermediate circuit) must be measured before working on the unit.
The maximum permissible voltage must be < 42 V.
High temperatures > 70 °C may occur.
Working environments may be hazardous for wearers of electronic medical devices.
(e.g. pacemakers) can be dangerous. A sufficient distance to these electrical parts must be maintained.
Stress
During transport and storage, the prescribed climatic conditions must be observed.
The units must not show any mechanical damage. Bent housing parts can damage the insulating
sections. Never install damaged units!
The units contain components that can be damaged by electrostatic discharge. The general
recommendations for handling ESD-components must be observed. Special attention must be paid to
highly insulating plastic foils and synthetic fibres.
For operation, it must be ensured that the environmental conditions in the control cabinet are complied
with. This applies in particular to the non-permitted condensation of the units.