background image

 

 

INSTRUCTIONS MANUAL 

 

 

 

UPC-8029 

 

LOCAL AIR CONDITIONER 

 

 

 

Read and save these instructions for future reference 

 

Summary of Contents for UPC-8029

Page 1: ...INSTRUCTIONS MANUAL UPC 8029 LOCAL AIR CONDITIONER Read and save these instructions for future reference...

Page 2: ...Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Please read these instructions before use and repair The drawings provided in this manual may no...

Page 3: ...in the use of flammable refrigerants 12 All working procedure that affects safety means shall only be carried by competent persons Notes The air conditioning is only suitable for indoor use and is not...

Page 4: ...nd understand the hazards involved Children shall not play with the appliance Cleaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replac...

Page 5: ...e control panel beautiful and fashionable with high quality remote control It adopts a user friendly remote control design Air filtration capability Timing switch function Protection function of autom...

Page 6: ...ht position and the air conditioning should be placed on a flat surface Do not install and use the air conditioning in the bathroom or other humid environments 1 1 Install the heat pipe assembly as sh...

Page 7: ...mponents of the assembly 1 2 Install the window sealing plate assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window and the distance between the body...

Page 8: ...Up Key 3 Down Key 4 Display Window 5 Fan Speed Selection Key 6 Mode Selection Key 7 Power Key When the machine is powered on for the first time the buzzer will play power on music and then the machine...

Page 9: ...timing in the case of power off press the key to open timing Press the key when the timing symbol flashes press up and down key to select the required timing value Timing values can be set in 1 24 hou...

Page 10: ...t to sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter After the water is emptied the machine will automatically return to the original state...

Page 11: ...water plug and tighten the drainage cover Notes 1 Restart the machine after the water plug and drainage cover are installed otherwise condensate water of the machine will flow to the floor or the car...

Page 12: ...ing to remove the EVA filter screen as shown in the above figure 2 Put the EVA filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean Unit Storag...

Page 13: ...being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigerat...

Page 14: ...safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If th...

Page 15: ...cumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 6 Leak detectio...

Page 16: ...not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them Cylinders shall be kept upright Ensure that the refrigerat...

Page 17: ...special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated an...

Page 18: ...ditioning by yourself Unqualified repair will lead to failure of the warranty card and may cause damage to users or their properties Problems Reasons Solutions The air conditioning does not work There...

Page 19: ...r The remote control is not aligned with the direction of the remote control receiver Batteries are dead Replace batteries Displays E1 The pipe temperature sensor is abnormal Check the pipe temperatur...

Page 20: ...collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product c...

Reviews: