Do not place the heater near walls, curtains of furniture while in operation. The
heater must be always facing towards the center of the room. The correct position
is indicated in the picture below:
The heater
must not
be moved while operating.
Do not place objects on or against the heater.
The grid on this appliance conforms to standard requirements. It does not give full
protection for young children. The grid is to prevent risk of injury and no part of it
should be removed or altered.
This appliance needs testing for gas leak before initial use and whenever the cylinder
has been reconnected after filled. NEVER USE A NAKED FLAME TO TEST FOR
POSSIBLE LEAKS.
Always turn off the gas cylinder valve whenever the heater is not in use.
BURN-BACK (FIRE IN BURNER TUBE OR CHAMBER)
In the event of a burn-back, where the flame burns back to the jet, immediately turn the gas
supply off at the control valve on the panel. After ensuring the flame is extinguished, wait for
1 minute and relight the appliance in the normal manner. If the appliance burns back again,
close the control valve and call a service technician. Do not use the appliance again until the
service technician has declared that it is safe for use.
GAS-PRESSURE REGULATOR
This appliance requires an operating pressure of 2,8 kPa at the appliance. A suitable LPG
regulator is included in the packaging.