Remark: “ERROR” will be displayed if the lock
-bolt is jammed. Please open the door again
to make certain that the door is closed normally.
Changing the Password
1.Changing the end user’s password.
By inserting the new 3-6 digit code
and “#” while the
safe is opened, the safe will be locked.
2.Changing the hotel management password. This need s to be operated while the safe is
locked. Double press “ *
”, the LCD will display “SUPER”.
Insert the hotel management
password (the factory se
t password for hotel is “000000”), the LCD will display “CC ——”.
Press “01” and “#”, the LCD will display “NEU”.
Insert the new 6 digit code as the
password, then press “#”
to confirm and
the LCD will display “REPEAT”
. Insert again the
new password and “#”
to confirm
, the LCD will display “GOOD”.
Normal Troubleshooting
Problem 1: Forgotten Administrator Password
Resolution:
1) Open the safe and remove the three screws on the back of the door.
2) Remove the door cover and press the black button for 5 seconds.
3) The LCD will display “RESET”,
the administration code will be changed into the initial
administrator password “000000”.
4) Close the door cover and tighten the screws and change the administrator password.
Problem 2: There is no display on the LCD
Reason: Maybe there is not enough power of the battery
Resolution: Change the battery with new one.
Problem 3: Cannot Change the Administrator or Guest Password
Reason: The lock-bolt does not come in contact with the limit switch
Resolution: Open the back door cover and fix the position of the limit switch.
Reason: The limit switch cannot operate or the connecting wire is broken.
Resolution: Open the back door cover and change the limit switch or connect the wire.
Problem 4: The Lock-bolt will rebound automatically when closing the safe
Reason: The door is not totally closed.
Resolution: Insert the password and close the door again.
Reason: The lock-bolt cannot make contact with the limit switch
Resolution: Open the back door cover and fix the position of the limit switch
Reason: The limit switch cannot operate or the connecting wire is broken
Resolution: Open the back door cover and change the limit switch or connect the wire
Problem 5: Cannot Close the Door if the door is imbalanced
Resolution: Use a 6mm Allen Key to remove the screws of the hinge.
Adjust the position of the safe door and tighten the screws.