III. A Variety of Protection Functions
3.1 Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of
the exhaust pipe is too low, the machine will automatically enter protection status;
if the temperature of the exhaust pipe rises to a certain temperature, it can
automatically revert to normal operation.
3.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will
automatically sound an alarm, and the "FULL" indicator light will flash. At this
point, you need to move the drainage pipe connecting the machine or the water
outlet to sewer or other drainage area to empty the water (details see
Drainage
Instruction
s at the end of this chapter). After the water is emptied, the machine will
automatically return to the original state.
3.3 Automatic Defrosting (cooling models have this function):
The machine has automatic defrosting function.
3.4. Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.