![United Technologies interlogix ACL805SUW-RDPX Installation Sheet Download Page 2](http://html1.mh-extra.com/html/united-technologies/interlogix-acl805suw-rdpx/interlogix-acl805suw-rdpx_installation-sheet_4043764002.webp)
© 2017 UTC Fire & Security. All rights reserved.
2 / 6
2017-10-13
Wiring
Figure 3: Wiring instructions
Specifications
Operating voltage
9 to 14 VDC
Current consumption
110 mA at 12 VDC
Interface Proximity Reader
Wiegand
according to the card type
Wiegand 32 bit :
EM410x Cards
Wiegand 40 bit :
Casi-Rusco
Automatic Wiegand -
HID Cards
EM410x
Wiegand 32 description
32 data bits
Pulse width: 100 µs
Pause: 1 ms
Wiegand for EM410x Cards
Casi-Rusco
Wiegand 40 description
even 38 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 1 to 19
P2 = odd parity calculated over the bits 0 to 39
Wiegand for Casi-Rusco cards
HID
Wiegand 26
– 37 bit
Automatic Wiegand according to the HID card type
Interface Keypad
Wiegand 26, 30, 34, 40, 42, 58 bit,
8 bit per key, 6 bit per key, 4 bit per key
Wiegand 26 description
even 24 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 13
P2 = odd parity calculated over the bits 14 to 25
Wiegand 30 description
even 28 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 15
P2 = odd parity calculated over the bits 16 to 29
Wiegand 34 description
even 32 data bits + odd parity
Pulse width: 100 µs
Pause: 1 ms
P1 = even parity calculated over the bits 2 to 17
P2 = odd parity calculated over the bits 18 to 33
1
tamp
Tamper
2
tamp
Tamper
3
LG-
LED Green minus
4
LR-
LED Red minus
5
GND
Ground
6
+12 V
9 to 14 VDC
7
D0
Data 0
8
D1
Data 1
gray
blue
yellow
orange
black
red
green
white
1
2
3
4
5
6
7
8
LR-
D1
D0
tamp
GND
+12 V
LG-
tamp