Furnace Installation
Dimension
Inches
A
Backwall to Appliance
17
B
Sidewall to Appliance
12
C
Backwall to Flue
23
D Sidewall to Flue
22.5
E
Supply Duct (first 6 feet)
6
F
Supply Duct (after first 6 feet)
1
G Minimum Duct height
6
H
Ceiling Height to Floor
84
J
Top of Door to Ceiling
48
*
Closest Point of Zero Clearance
2’
INSTALLATION OPTIONS
The installation of this furnace includes supplying electrical power, return (fresh air) ductwork, and supply air
ductwork. This furnace may be installed as a stand alone wood furnace.
See kit installation section in this manual to ensure proper assembly, installation and operation of your new
furnace.
If installing in an area with a fan it should not be allowed to create negative pressure in the room where the
furnace is installed.
LOCATING YOUR FURNACE
(INSURE THAT THE REQUIRED MAINTENANCE CLEARANCES ARE MAINTAINED)
Your furnace must be installed as shown in this manual and in compliance with all local and national codes.
It is of the utmost importance that the clearances to combustible materials be strictly adhered to during
installation of the furnace. Refer to the table and diagrams below for minimum required clearances.
Ceiling
E
F
J
H
G
Back wall
Side w
all
Side w
all
B
D
A
C
CLEARANCE TO COMBUSTIBLES
CLEARANCE TO COMBUSTIBLES
Summary of Contents for Clayton CL1660E
Page 9: ...9 INSTALLATION ADD ON INSTALLATION...
Page 27: ...27...