27
10. Operation
10.1 Connect and Charge
10.2 Stop Charging
10.3 Self-Monitoring and Recovery (Auto Restart)
Insert the charging Connector into the EV and ensure the connector is fully seated/locked in
place. Once complete, the charging session will begin.
Charging will start in both Connected Mode (Light Blue indicator LED) and Standard Mode
(Purple indicator LED).
1. Unplug the charging station by pressing the connector button and removing the Charger
Connector from the EV (once the connector button is depressed, the charging session
terminates immediately).
2. Return the connector to the holster.
When a charging session is interrupted due to a temporary error condition, it will
automatically restart charging when the cause of the temporary error condition returns to
normal. The status indicator lights remain flashing RED until the error condition
is resolved.
• Temporary error conditions include: Over Current, Under Voltage, Missing Diode, Ground
Fault, and Over Temperature.
• The charging session will show a Red Flashing Indicator Light and the charging session will
stop.
• The charger will attempt to restart every 30 seconds. If the error condition is resolved the
charging station will automatically restart.
• The charging station will attempt to restart everry thirty seconds. After 4 times, the
charging station buzzer will stay on continuously, and status indicator will stay RED. The
user should plug-out and plug-in the power cable of the charging station.
• If the Red Steady indicator light and buzzer remain, contact the United Chargers Technical
Support Team.
Figure 3-1. Connect the charging plug to the EV