Convert UPC-E to UPC-A
Convert UPC-E to UPC-A (Enable/Disable)
Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format
before transmission. After conversion, the data follows UPC-A format and is
affected by UPC-A programming selections (e.g., Preamble, Check Digit).
Disable this to transmit UPC-E decoded data as UPC-E data, without conversion.
Convert UPC-E1 to UPC-A
Convert UPC-E1 to UPC-A (Enable/Disable)
Enable this to convert UPC-E1 decoded data to UPC-A format before transmission.
After conversion, the data follows UPC-A format and is affected by UPC-A
programming selections (e.g., Preamble, Check Digit).
Disable this to transmit UPC-E1 decoded data as UPC-E1 data, without conversion.
Convert Code 39 to Code 32
Convert Code 39 to Code 32 (Enable/Disable)
Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan
the appropriate barcode below to enable or disable converting Code 39 to Code 32.
Note:
Code 39 must be enabled for this parameter to function.
52
Copyright 2013 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.