Unitech MS140 User Manual Download Page 5

Selectable Parameters and their Defaults 

Parameters 

Selections 

Default 

Keyboard Wedge 
Device Selection 

IBM PC/AT, PS/2 mod 40, 60, 80 etc 
IBM PS/2 Model 25, 56, 70, 90 
Macintosh ADB bus 
Keyboardless Wedge (Notebook) 

IBM 
PC/AT 

RS232 Interface 
Baud Rate 

0-300; 1-600; 2- 1200; 3-2400; 4-4800; 
5-9600; 6-19200 

9600

 

Parity 

0-Even;1-Odd;2-Mark;3-Space;4-None 

None 

Data bits 

0-7 bits; 1-8 bits 

8 bits 

CTS/RTS 

0-Ignore; 1-RTS Enabled at Power on; 2- 
RTS Enabled in communication 

Ignore 

ACK/NAK 

0-Off; 1-On 

Off

 

BCC Character 

0-Off; 1-On 

Off 

Xon/Xoff Time out  0-1 sec; 1-3 sec; 2-10 sec; 3-Unlimited 

1 sec

 

Beep Tone 

None/Low/Medium/High/Low to High/ 
High to Low 

Medium 

Beep Tone 
(On ACK) 

None/Low/Medium/High/Low to High/ 
High to Low 

High 

Intercharacter delay  0 ms/1 ms/2 ms/5 ms/10 ms/30 ms/50 

ms/100 ms 

0 ms 

Interblock delay 

0 ms/10 ms/50 ms/100 ms/500 ms/1 
second/3 second/5 second 

0 ms 

Function Code 

On/Off 

On 

CapsLock 

Auto_trace/Low Case/Upper Case 

Auto_trace 

Language 

US/UK/Swiss/Swedish/Spanish/ 
Norwegian/Italian/German/French/ 
Alt Key Mode/Danish 

US 

Double verification 

Off/1~7 On(Verify 1~7 times) 

Off 

Label Type

 

Positive /Positive and Negative 

Positive 

Output of Wand 

Bar high, space low/ 
Bar low, space high 

Bar high, 
space low 

Level Duration 

200 us/600 us 

200 us 

Terminator 

Enter/Return /Field Exit/None 

Enter 

Code ID 

Disable/Enable 

Disable 

Define Code ID

 

00- Code 39 Full ASCII 
01- Code 39 Standard  
02- EAN-13 
03- UPC-A 
04- EAN-8 
05- UPC-E 
06- I 2 of 5 
07- Codabar 

10- S 2 of 5 
11- MSI 
12- EAN 128 
13- Code 32 
14- Delta Code 
15- Label Code 
16- Plessey Code 
17- Code 11 

Summary of Contents for MS140

Page 1: ...1 User s Manual MS140 3 or MS140I 3 Keyboard Wedge Slot Reader PC Keyboard Wedge Setup Label ...

Page 2: ...rd of a desktop PC Or By Scanner Configuration Manager Software to configure the scanner setting through the keyboard port Or By using the custom labels batch setup Installation The picture below illustrates how to connect the reader to your computer Follow these procedures for installation 1 Turn off computer power 2 Unplug keyboard from computer Plug the reader into computer s keyboard port and ...

Page 3: ...up label if you have this manual handy Or Use custom labels batch setup When the reader enters the setup mode a selection menu will be displayed on the screen Please refer to the MS140 Setup Manual Section MS140 2 RS232 Wedge Setup of the RS232 wedge reader can be done in two different ways Through a modem communication utility such as HyperTerminal Or Via custom labels batch setup Installation Th...

Page 4: ...the user to input ASCII characters into a string Batch Setup If more than one scanner needs to be configured you can duplicate the settings of the Master Scanner to the others This is done by producing a set of custom setup labels derived from the master scanner and then scanning these labels to configure the other scanners Selecting the Dump command in setup mode or swiping the Dump Setting label...

Page 5: ...ow Medium High Low to High High to Low High Intercharacter delay 0 ms 1 ms 2 ms 5 ms 10 ms 30 ms 50 ms 100 ms 0 ms Interblock delay 0 ms 10 ms 50 ms 100 ms 500 ms 1 second 3 second 5 second 0 ms Function Code On Off On CapsLock Auto_trace Low Case Upper Case Auto_trace Language US UK Swiss Swedish Spanish Norwegian Italian German French Alt Key Mode Danish US Double verification Off 1 7 On Verify ...

Page 6: ...uppressed Min 4 Max 64 10 64 Standard 2 of 5 Disable Enable Disable Toshiba Fix Length On Off On Check Digit Check and Send Check but Not Send Not Check Not Check Min 1 Max 48 4 48 Code 32 Disable Enable Disable Leading Character Send No Send Send Tailing Character Send No Send Send Telepen Disable Enable Disable Standard Numeric Set Standard Disable Enable Enable UCC EAN 128 Code ID Disable Enabl...

Page 7: ...ng Digit Send No Send Send CD Send No Send No Send Zero Expansion On Off Off Disable Enable NSC 1 Disable EAN 13 Disable Enable Enable Leading Digit Send No Send Send CD Send No Send Send Bookland EAN Enable Disable Disable EAN 8 Disable Enable Enable Leading Digit Send No Send Send CD Send No Send Send Supplement Code Two Add on Code Off On Off Five Add on Code Off On Off Transmitted if Present M...

Page 8: ...8 User s Manual MS140 2 or MS140I 2 RS232 Interface Slot Reader RS232 Interface Setup Label ...